Read JBL ON TIME MICRO (serv.man2) EMC - CB Certificate online
- Page 13 of 39 -
Report No. NTEK-2011NT1009318S
EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
NTEK Testing Technology Co., Ltd.
13.5 Printed
boards
N
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
N
13.5.2
Type B coated printed circuit boards complying
with IEC 60 664-3 (basic insulation only)
with IEC 60 664-3 (basic insulation only)
N
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
clearances and creepage distances comply with
13.3 and 13.4
N
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N
13.7
Enclosed, enveloped or hermitically sealed parts:
not conductively connected to the mains:
clearances and creepage distances as in Table 12
not conductively connected to the mains:
clearances and creepage distances as in Table 12
Not such a construction.
N
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
N
14
COMPONENTS (The approved Class II switching power supply
be used.)
be used.)
P
14.1 Resistors
N
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
N
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
N
b) Resistors separately approved .......................... :
N
14.2
Capacitors and RC units
N
Capacitors separately approved
N
14.2.1
Y capacitors tested to IEC 384-14, 2nd edition ..... :
N
14.2.2
X capacitors tested to IEC 384-14, 2nd edition ..... :
N
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ...................... :
connected to the mains: tests for X2 ...................... :
N
14.2.5
Capacitors with volume exceeding 1750 mm³,
where short-circuit current exceeds 0,2 A:
compliance with IEC 60 384-1, 4.38 category B or
better ....................................................................... :
where short-circuit current exceeds 0,2 A:
compliance with IEC 60 384-1, 4.38 category B or
better ....................................................................... :
N
Click on the first or last page to see other ON TIME MICRO (serv.man2) service manuals if exist.