Report No. NTEK-2011NT1009318S 
 EN 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
NTEK Testing Technology Co., Ltd. 
 
3 GENERAL 
REQUIREMENTS 
 
Safety class of the apparatus ................................. : The approved Class II 
switching power supply be 
used. 
 
GENERAL CONDITIONS OF TESTS 
4.1.4 Ventilation 
instructions 
require the use of the test 
box 
Yes 
 
5 MARKING 
 
Comprehensible and easily discernible 
All markings are printed on 
label pasted on outer 
enclosures of the appliance. 
 
Permanent durability against water and petroleum 
spirit 
After rubbing test by water and 
petroleum spirit, the label still 
easily discernible, indelible and 
legible. 
5.1 
a) Identification, maker, model  ............................... : See the label 
 
b) Model number or type reference 
jbl on time™  micro 
 
c) Class II symbol 
...........................................:
 
Marking on the switching 
power supply. 
 
d) Nature of supply
...........
 
...........................
IEC 60417-5032 symbol used 
 
e) Rated supply voltage .......................................... : AM/FM Radio & Speaker Dock 
For Ipod/Iphone: DC12V 
Switching power supply: 100-
240Vac 
 
f) Mains frequency if safety dependant ...................:
Switching power supply: 
50/60Hz 
 
g) Rated current or power consumption for 
apparatus supplied by supply apparatus for general
use ...........................................................................:
 
 
Measured current or power consumption ...............:
(See appended table 7.1) 
 
Deviation % (max 10%) ...........................................:
(See appended table 7.1) 
 
h) Rated current or power consumption for 
apparatus intended for connection to an a.c. mains 
supply.: 
 
 
Measured current or power consumption ...............:
Not Television set. 