Read JBL ON TIME MICRO (serv.man2) EMC - CB Certificate online
- Page 16 of 39 -
Report No. NTEK-2011NT1009318S
EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
NTEK Testing Technology Co., Ltd.
Switch controlling > 0.2A with open contact voltage
> 35 V (peak) / 24 V dc complying with 14.6.3 and
V-0 in annex G, G.1.1
> 35 V (peak) / 24 V dc complying with 14.6.3 and
V-0 in annex G, G.1.1
N
Switch controlling > 0.2A with open contact voltage
> 35 V (peak) / 24 V dc complying with 14.6.4 and
V-0 in annex G, G.1.1
> 35 V (peak) / 24 V dc complying with 14.6.4 and
V-0 in annex G, G.1.1
N
14.6.2
Switch tested to 14.6.1 b) constructed to IEC
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
N
14.6.3
Switch tested to 14.6.1 b) constructed to IEC
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in used
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in used
N
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
strength
N
14.6.5
Mains switch controlling mains socket-outlets
additional tests to IEC 60058-1
additional tests to IEC 60058-1
N
Socket-outlet current marking correct
N
14.7
Safety interlocks
N
Safety interlocks to 2.8 of IEC 60 950
N
14.8
Voltage setting devices
N
Voltage setting device not likely to be changed
accidentally
accidentally
N
14.9
Motors
N
14.9.1
Endurance test on motors
N
Motor start test
N
Dielectric strength test
N
14.9.2
Not adversely affected by oil or grease etc.
N
14.9.3
Protection against moving parts
N
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet Cl. B.8, B.9 and
B.10 of IEC 60 950, Annex B
motors and series motors meet Cl. B.8, B.9 and
B.10 of IEC 60 950, Annex B
N
14.10 Batteries
N
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
flammable gases
N
14.10.2
No possibility of recharging non-rechargeable
batteries
batteries
N
Click on the first or last page to see other ON TIME MICRO (serv.man2) service manuals if exist.