ON TIME MICRO (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 16

Read JBL ON TIME MICRO (serv.man2) EMC - CB Certificate online

 
- Page 16 of 39 - 
 
 
 
Report No. NTEK-2011NT1009318S 
 EN 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
NTEK Testing Technology Co., Ltd. 
 
 
Switch controlling > 0.2A with open contact voltage 
> 35 V (peak) / 24 V dc complying with 14.6.3 and 
V-0 in annex G, G.1.1 
 N 
 
Switch controlling > 0.2A with open contact voltage 
> 35 V (peak) / 24 V dc complying with 14.6.4 and 
V-0 in annex G, G.1.1 
 N 
14.6.2 
Switch tested to 14.6.1 b) constructed to IEC 
61058-1 subclause 13.1 and has making/breaking 
action independent of speed of actuation 
 N 
14.6.3 
Switch tested to 14.6.1 b) constructed to IEC 
61058-1 subclause 16.2.2 d) and m) not attaining 
excessive temperatures in used  
 N 
14.6.4 
Switch tested to 14.6.1 b) has adequate dielectric 
strength  
 N 
14.6.5 
Mains switch controlling mains socket-outlets 
additional tests to IEC 60058-1 
 N 
 
Socket-outlet current marking correct 
 
14.7 
Safety interlocks 
  
 
Safety interlocks to 2.8 of IEC 60 950 
 
14.8 
Voltage setting devices 
 
 
Voltage setting device not likely to be changed 
accidentally 
 N 
14.9 
Motors                                                                            
14.9.1 
Endurance test on motors 
 
 
Motor start test 
 
 
Dielectric strength test 
 
14.9.2 
Not adversely affected by oil or grease etc. 
 
14.9.3 
Protection against moving parts 
 
14.9.4 
Motors with phase-shifting capacitors, three-phase 
motors and series motors meet Cl. B.8, B.9 and 
B.10 of IEC 60 950, Annex B 
 N 
14.10 Batteries 
14.10.1 
Batteries mounted with no risk of accumulation of 
flammable gases 
  
14.10.2 
No possibility of recharging non-rechargeable 
batteries 
 N 
Page of 39