Report No. NTEK-2011NT1009318S 
 EN 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
NTEK Testing Technology Co., Ltd. 
 
 
Not possible to push cord back into equipment 
 
 
Strain relief device unlikely to damage flexible cord  
 
For mains cords of Class I equipment, hazardous 
live conductors become taut before earth 
conductor 
  
16.6 
Apertures for external flexible cord: no risk of 
damage to the cord during assembly or movement 
in use 
 N 
16.7 
Transportable musical instruments and amplifiers 
fitted with detachable cord set with appliance inlet 
to IEC 60 320-1 
 N 
 
Transportable musical instruments and amplifiers 
fitted with detachable cord sets or with means of 
stowage to protect the cord 
 N 
 
 
17 ELECTRICAL 
CONNECTIONS 
AND MECHANICAL FIXINGS 
17.1 
Torque test to Table 20: 
 
- screws into metal: 5 times 
 
 
- screws into non-metallic material: 10 times 
 
 
P
 
17.2 
Correct introduction into female threads in non-
metallic material 
 
N 
17.3 
Cover fixing screws: captive 
See below. 
 
Non-captive fixing screws: no hazard when 
replaced by a screw whose length is 10 times its 
diameter 
 N 
17.4 
No loosening of conductive parts carrying a current 
> 0,2 A 
No such means. 
17.5 
Contact pressure not transmitted through plastic 
other than ceramic for connections carrying a 
current > 0,2 A 
No contact pressure by 
screws. 
17.6 
Stranded conductors of flexible supply cords 
carrying a current > 0,2 A with screw terminals not 
consolidated by solder 
 N 
17.7 
Cover fixing devices other than screws have 
adequate strength and their positioning is 
unambiguous 
See 17.1 
17.8 
Fixing devices for detachable legs or stands 
provided 
No detachable legs or stands. 