Read JBL ON TIME MICRO (serv.man2) EMC - CB Certificate online
- Page 20 of 39 -
Report No. NTEK-2011NT1009318S
EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
NTEK Testing Technology Co., Ltd.
Not possible to push cord back into equipment
N
Strain relief device unlikely to damage flexible cord
N
For mains cords of Class I equipment, hazardous
live conductors become taut before earth
conductor
live conductors become taut before earth
conductor
N
16.6
Apertures for external flexible cord: no risk of
damage to the cord during assembly or movement
in use
damage to the cord during assembly or movement
in use
N
16.7
Transportable musical instruments and amplifiers
fitted with detachable cord set with appliance inlet
to IEC 60 320-1
fitted with detachable cord set with appliance inlet
to IEC 60 320-1
N
Transportable musical instruments and amplifiers
fitted with detachable cord sets or with means of
stowage to protect the cord
fitted with detachable cord sets or with means of
stowage to protect the cord
N
17 ELECTRICAL
CONNECTIONS
AND MECHANICAL FIXINGS
P
17.1
Torque test to Table 20:
P
- screws into metal: 5 times
N
- screws into non-metallic material: 10 times
P
17.2
Correct introduction into female threads in non-
metallic material
metallic material
N
17.3
Cover fixing screws: captive
See below.
N
Non-captive fixing screws: no hazard when
replaced by a screw whose length is 10 times its
diameter
replaced by a screw whose length is 10 times its
diameter
N
17.4
No loosening of conductive parts carrying a current
> 0,2 A
> 0,2 A
No such means.
N
17.5
Contact pressure not transmitted through plastic
other than ceramic for connections carrying a
current > 0,2 A
other than ceramic for connections carrying a
current > 0,2 A
No contact pressure by
screws.
screws.
N
17.6
Stranded conductors of flexible supply cords
carrying a current > 0,2 A with screw terminals not
consolidated by solder
carrying a current > 0,2 A with screw terminals not
consolidated by solder
N
17.7
Cover fixing devices other than screws have
adequate strength and their positioning is
unambiguous
adequate strength and their positioning is
unambiguous
See 17.1
N
17.8
Fixing devices for detachable legs or stands
provided
provided
No detachable legs or stands.
N
Click on the first or last page to see other ON TIME MICRO (serv.man2) service manuals if exist.