Read JBL ON TIME MICRO (serv.man2) EMC - CB Certificate online
- Page 19 of 39 -
Report No. NTEK-2011NT1009318S
EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
NTEK Testing Technology Co., Ltd.
15.3.8
Terminals carrying a current more than 0,2 A:
contact pressure not transmitted by insulating
material except ceramic
contact pressure not transmitted by insulating
material except ceramic
No such terminal.
N
15.3.9
Termination of non-detachable cords: wires
terminated near to each other
terminated near to each other
N
Terminals located and shielded: test with 8 mm
strand
strand
N
15.4
Devices forming a part of the mains plug
N
15.4.1
No undue strain on mains socket-outlets
The approved Class II
switching power supply be
used.
switching power supply be
used.
N
15.4.2
Device complies with standard for dimensions of
mains plugs
mains plugs
N
15.4.3
Device has adequate mechanical strength (tests
a,b,c)
a,b,c)
N
16
EXTERNAL FLEXIBLE CORDS
(The approved Class II switching power supply be used.)
N
16.1
Mains cords sheathed type, complying with
IEC 60 227 for PVC or IEC 60 245 for synthetic
rubber cords ............................................................ :
IEC 60 227 for PVC or IEC 60 245 for synthetic
rubber cords ............................................................ :
The approved Class II
switching power supply be
used.
switching power supply be
used.
N
Non-detachable cords for Class I have
green/yellow core for protective earth
green/yellow core for protective earth
N
16.2
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the
equipment
sectional area for rated current consumption of the
equipment
N
16.3
a) Flexible cords not complying with 16.1, used for
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
N
b) Flexible cords not complying with 16.1,
withstand bending and mechanical stress (3.2 of
IEC 60 227-2)
withstand bending and mechanical stress (3.2 of
IEC 60 227-2)
N
16.4
Flexible cords used for connection between
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
N
16.5
Adequate strain relief on external flexible cords
N
Click on the first or last page to see other ON TIME MICRO (serv.man2) service manuals if exist.