ON STAGEII (serv.man6) - JBL Audio EMC - CB Certificate (repair manual). Page 50

Read JBL ON STAGEII (serv.man6) EMC - CB Certificate online

Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
Janurary 5,2006 
Harman Multimedia  OnStage UD    CE Test Report 
2006 011114 CE AUS/NZ 
 
50 of 72 
 
4.6.  Power Line Surge Immunity Test Results 
Client 
Harman Multimedia 
Temperature 70 
deg 
PAN # 
25-1114-HAR 
Relative Humidity 
49 
EUT Name 
Computer Speaker System 
Barometric Pressure 
30.5 
Hg 
EUT Model  
OnStage UD 
Test Location 
Enclosure 1 
Governing Doc 
EN 55024 
Test Engineer 
Rodel Resolme 
Basic Standard 
IEC 61000-4-5 
Date 
01/03/06 
 
 
 
 
 
 
 
 
 
 
EUT Power: 
Number of Strikes per Polarity/Voltage: 
Repetition # Angle 
 
X  230VAC @ 50Hz 
X  Five (5) 
0º 
 
 
230/400VAC @ 50 Hz 
 
Twenty (20) 
90º 
 
 
120VAC @ 60 Hz 
 
 
180º 
    
   
270º 
  
360º 
 
 
 
Waveform Generator Type: 
 Ring 
Wave   Combination 
 
 
 
Test Equipment: Asset 
# Used Calibration 
Done Calibration 
Due 
EMC Partner 2000 
845 
4/15/05 
4/15/06 
 
 
 
 
 
 
 
 
 
 
 
 
Performance 
Criteria:  X 
A    B    C 
 
 
L - Gnd 
0.5kV (Level 1) 
1.0kV (Level 2) 
2.0kV (Level 3) 
4.0kV (Level 4) 
??kV (Special) 
L - L 
0.25kV (Level 1) 
0.5kV (Level 2) 
X 1.0kV (Level 3) 
2.0kV (Level 4) 
??kV (Special) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Level 1 
Level 2 
Level 3 
Level 4 
Special 
 
CM  DM  CM  DM  CM  DM  CM DM CM DM 
 0.5kV 
0.25kV 
1.0kV 
0.5kV 
2.0kV 
1.0kV 
4.0kV 
2.0kV  
 
 
+ - + - + - + - + - + - + - + - + - + - 
N–Gnd    
   
   
   
   
L1–Gnd    
 
 
 
 
 
 
 
 
 
 
 
 
 
N-L1 
 
X X 
 
X X 
 
X X 
 
 
 
 
 
 
 
 
Compliant   X   
Non-Compliant
 
 
Photo 
X   
 
Page of 72
Display

Click on the first or last page to see other ON STAGEII (serv.man6) service manuals if exist.