Read JBL ON STAGEII (serv.man6) EMC - CB Certificate online
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
Janurary 5,2006
Harman Multimedia OnStage UD CE Test Report
2006 011114 CE AUS/NZ
47 of 72
4.4. Radio Frequency Immunity Test Results
Client:
Harman Multimedia
Temperature: 72
degF
PAN #:
25-1114-HAR
Relative Humidity:
48
%
EUT Name:
Computer Speaker System
Barometric Pressure:
30.5
Hg
EUT Model:
OnStage UD
Test Location:
Anachoic Chamber
Governing Doc:
EN 55024
Test Engineer:
Rodel Resolme
Basic Standard:
IEC 61000-4-3
Date:
01/04/06
Voltage: 230VAC/
50Hz
Threat Levels
Frequency (MHz):
27-500
X
80-1000
26-1000
Test Level:
1V/m
X
3V/m
10V/m
200V/m
Modulation:
None (CW)
X 80% AM, 1kHz
50% PM, 200Hz
Frequency Step:
X
1%
3%
Dwell Time:
1 sec
X 3 sec
10 sec
Criteria:
X
A
B
C
Antenna
Polarization
Compliant
Frequency (MHz)
H V Y N
Orientation
F: Front
R: Rear
SL: Side, Left
SR: Side, Right
F: Front
R: Rear
SL: Side, Left
SR: Side, Right
Comments
80-200
X X
F
No
disruption
80-200
X X
F
No
disruption
80-200
X X
R
No
disruption
80-200
X X
R
No
disruption
200-1000
X X
R
No
disruption
200-1000
X X
R
No
disruption
200-1000
X X
F
No
disruption
200-1000
X X
F
No
disruption
Compliant X
Not
Compliant
Photo X
Click on the first or last page to see other ON STAGEII (serv.man6) service manuals if exist.