ON STAGEII (serv.man6) - JBL Audio EMC - CB Certificate (repair manual). Page 47

Read JBL ON STAGEII (serv.man6) EMC - CB Certificate online

Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
Janurary 5,2006 
Harman Multimedia  OnStage UD    CE Test Report 
2006 011114 CE AUS/NZ 
 
47 of 72 
 
4.4.  Radio Frequency Immunity Test Results 
Client: 
Harman Multimedia 
Temperature: 72 
degF 
PAN #: 
25-1114-HAR 
Relative Humidity: 
48 
EUT Name: 
Computer Speaker System 
Barometric Pressure: 
30.5 
Hg 
EUT Model: 
OnStage UD 
Test Location: 
Anachoic Chamber 
Governing Doc: 
EN 55024 
Test Engineer: 
Rodel Resolme 
Basic Standard: 
IEC 61000-4-3 
Date: 
01/04/06 
Voltage: 230VAC/ 
50Hz 
Threat Levels 
Frequency (MHz): 
 27-500 
80-1000 
 26-1000 
  
Test Level: 
 1V/m 
3V/m 
 10V/m 
 200V/m 
Modulation: 
 
None (CW) 
X  80% AM, 1kHz 
 
50% PM, 200Hz 
 
 
Frequency Step: 
1% 
 3% 
  
  
Dwell Time: 
 
1 sec 
X  3 sec 
 
10 sec 
 
 
Criteria: 
 B 
 C 
  
Antenna 
Polarization 
Compliant 
Frequency (MHz) 
H V Y N 
Orientation 
F: Front 
R: Rear 
SL: Side, Left 
SR: Side, Right 
Comments 
80-200 
 X X  
No 
disruption 
80-200 
X  X  
No 
disruption 
80-200 
X  X  
No 
disruption 
80-200 
 X X  
No 
disruption 
200-1000 
 X X  
No 
disruption 
200-1000 
X  X  
No 
disruption 
200-1000 
X  X  
No 
disruption 
200-1000 
 X X  
No 
disruption 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Compliant  X  
Not 
Compliant     
Photo  X  
 
Page of 72