Read JBL ON STAGEII (serv.man6) EMC - CB Certificate online
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
Janurary 5,2006
Harman Multimedia OnStage UD CE Test Report
2006 011114 CE AUS/NZ
52 of 72
4.8. Voltage Dips and Interruptions Immunity Test Results
Client
Harman Multimedia
Temperature 72
deg
F
PAN #
25-1114-HAR
Relative Humidity
48
%
EUT Name
Computer Speaker System
Barometric Pressure
30.5
Hg
EUT Model
OnStage UD
Test Location
West Ground Plane
Governing Doc
EN 55024
Test Engineer
Rodel Resolme
Basic Standard
IEC 61000-4-11
Date
01/04/06
EUT Voltage:
X 230VAC @ 50Hz
120VAC @ 60Hz
Equipment Used Used Asset
# Cal
Done Cal
Due
EMC Partner 2000
X
845 10/30/05
02/28/06
Xitron 2520 Standard Impedance
581
Xitron 2503AH Power Analysis System
582
Changes Occur At: Zero
Crossing
Voltage Dips
Criteria Compliance
% Reduction Duration
sec/period
A
B
C Yes No
X >95%
10msec / 0.5
X
X
30%
10msec / 0.5
X 30%
500msec / 25
X
X
60%
100 msec / 5
Not
Required
Voltage Interruptions
Criteria Compliance
% Reduction Duration
sec/period
A
B
C Yes No
X >95%
5000msec / 250
X
X
100%
20msec / 1.0
Not
Required
Photo
X