ON STAGEII (serv.man6) - JBL Audio EMC - CB Certificate (repair manual)

Model
ON STAGEII (serv.man6)
Pages
72
Size
1.72 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
on-stageii-sm6.pdf
Date

View JBL ON STAGEII (serv.man6) EMC - CB Certificate online

Nemko USA, Inc. 
11696 Sorrento Valley Rd., Suite F 
San Diego, CA 92121-1024 
Phone (858) 755-5525   Fax (858) 452-1810 
 
EMC
 
D
IRECTIVE 
89/336/EEC 
 
 
 
CE
 
E
VALUATION
 
 
T
EST 
R
EPORT
 
 
PER 
EN
 
55022
 AND 
EN
 
55024 
 
For The
 
Computer Speaker System 
Model: 
OnStage UD
 
 
 
 
 
 
P
REPARED FOR
 
Harman Multimedia 
8500 Balboa Blvd. 
Northridge, CA  91329 
 
 
 
 
 
 
 
P
REPARED ON 
Janurary 5,2006 
 
R
EPORT 
N
UMBER 
2006 011114 CE AUS/NZ 
 
 
PROJECT NUMBER:  25-1114-HAR 
 
 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
Janurary 5,2006 
Harman Multimedia  OnStage UD    CE Test Report 
2006 011114 CE AUS/NZ 
 
2 of 72 
 
 
DOCUMENT HISTORY 
 
REVISION DATE 
COMMENTS 
Janurary
 5,2006
 
Prepared By:  
Rodel Resolme 
Janurary
 5,2006
 
Initial Release: 
Chip Fluery 
 
NOTE:  Nemko USA, Inc. hereby makes the following statements so as to conform to Chapter 10 (Test 
Reports) Requirements of ANSI C63.4 (1992) “Methods and Measurement of Radio-Noise Emissions from 
Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz”: 
 
o
  The unit described in this report was received at Nemko USA, Inc.'s facilities on  January 3, 
2005 .  
o
  The Test Results reported herein apply only to the Unit actually tested, and to substantially 
identical Units. 
o
  This report does not imply the endorsement of the Federal Communications Commission (FCC), 
NVLAP or any other government agency. 
 
This Report is the property of Nemko USA, Inc., and shall not be reproduced, except in full, without prior 
written approval of Nemko USA, Inc.  However, all ownership rights are hereby returned unconditionally to 
Harman Multimedia, and approval is hereby granted to Harman Multimedia and its employees and agents 
to reproduce all or part of this report for any legitimate business purpose without further reference to Nemko 
USA, Inc. 
 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
Janurary 5,2006 
Harman Multimedia  OnStage UD    CE Test Report 
2006 011114 CE AUS/NZ 
 
3 of 72 
 
TABLE OF CONTENTS 
DOCUMENT HISTORY .................................................................................................................................. 2
 
CERTIFICATION ............................................................................................................................................. 5
 
1.
 
ADMINISTRATIVE DATA AND TEST SUMMARY ......................................................................... 6
 
1.1.A
DMINISTRATIVE 
D
ATA
.................................................................................................................................. 6
 
1.2.T
EST 
S
UMMARY
.............................................................................................................................................. 7
 
2.
 
SYSTEM CONFIGURATION ................................................................................................................ 9
 
2.1.S
YSTEM 
C
OMPONENTS AND 
P
OWER 
C
ABLES
.................................................................................................. 9
 
2.2.D
EVICE 
I
NTERCONNECTION AND 
I/O
 
C
ABLES
................................................................................................. 9
 
2.3.D
ESCRIPTION AND 
M
ETHOD OF 
E
XERCISING THE 
EUT ................................................................................. 10
 
2.4.D
ESIGN 
M
ODIFICATIONS FOR 
C
OMPLIANCE
.................................................................................................. 10
 
3.
 
DESCRIPTION OF TESTING METHODS ........................................................................................ 11
 
3.1.I
NTRODUCTION
............................................................................................................................................. 11
 
3.2.C
ONFIGURATION AND 
M
ETHODS OF 
M
EASUREMENTS FOR 
C
ONDUCTED 
E
MISSIONS
..................................... 16
 
3.3.C
ONFIGURATION AND 
M
ETHODS OF 
M
EASUREMENTS FOR 
F
REQUENCY 
I
DENTIFICATION
............................. 18
 
3.4.C
ONFIGURATION AND 
M
ETHODS OF 
M
EASUREMENTS FOR 
R
ADIATED 
E
MISSIONS
........................................ 20
 
3.5.S
TATISTICAL 
S
AMPLING 
R
EQUIRED FOR 
C
ONTINUED 
C
OMPLIANCE
.............................................................. 22
 
3.6.P
OWER 
L
INE 
H
ARMONICS
:
 
EN
 
61000-3-2
 
(2000),
 
A1(2001),
 
A2(2005) ...................................................... 22
 
3.7.P
OWER 
L
INE 
F
LUCTUATIONS
/F
LICKER
:
 
EN
 
61000-3-3
 
(1995),
 
A1(2001) .................................................... 23
 
3.8.D
EVICE 
P
ERFORMANCE 
C
RITERIA FOR 
I
MMUNITY 
T
ESTS
.............................................................................. 25
 
3.9.E
LECTROSTATIC 
D
ISCHARGE 
I
MMUNITY
:
 
IEC
 
61000-4-2
 
(2001) ................................................................. 26
 
3.10.R
ADIO 
F
REQUENCY 
I
MMUNITY
:
 
IEC
 
61000-4-3
 
(2002) .............................................................................. 28
 
3.11.E
LECTRICAL 
F
AST 
T
RANSIENT 
I
MMUNITY
:
 
IEC
 
61000-4-4
 
(2004) ............................................................. 30
 
3.12.P
OWER 
L
INE 
S
URGE 
I
MMUNITY
:
 
IEC
 
61000-4-5
 
(2001) ............................................................................. 32
 
3.13.R
ADIO 
F
REQUENCY 
C
ONDUCTED 
C
OMMON 
M
ODE 
I
MMUNITY
:
 
IEC
 
61000-4-6
 
(2004) .............................. 34
 
3.14.P
OWER 
F
REQUENCY 
M
AGNETIC 
F
IELD 
I
MMUNITY
:
 
IEC
 
61000-4-8
 
(2001)................................................. 36
 
3.15.V
OLTAGE 
D
IPS AND 
S
HORT 
I
NTERRUPTIONS
:
 
IEC
 
61000-4-11(2004) ........................................................ 38
 
4.
 
TEST RESULTS ..................................................................................................................................... 40
 
4.1.C
ONDUCTED 
E
MISSIONS 
T
EST 
D
ATA
............................................................................................................ 40
 
4.2.R
ADIATED 
E
MISSIONS 
T
EST 
D
ATA
................................................................................................................ 43
 
4.3.E
LECTROSTATIC 
D
ISCHARGE 
I
MMUNITY 
T
EST 
R
ESULTS 
&
 
T
EST 
P
OINTS
...................................................... 45
 
4.4.R
ADIO 
F
REQUENCY 
I
MMUNITY 
T
EST 
R
ESULTS
............................................................................................. 47
 
4.5.E
LECTRICAL 
F
AST 
T
RANSIENT 
B
URST 
I
MMUNITY 
T
EST 
R
ESULTS
................................................................. 49
 
4.6.P
OWER 
L
INE 
S
URGE 
I
MMUNITY 
T
EST 
R
ESULTS
............................................................................................ 50
 
4.7.RF
 
C
ONDUCTED 
C
OMMON 
M
ODE 
D
ISTURBANCE 
I
MMUNITY 
T
EST 
R
ESULTS
................................................ 51
 
4.8.V
OLTAGE 
D
IPS AND 
I
NTERRUPTIONS 
I
MMUNITY 
T
EST 
R
ESULTS
................................................................... 52
 
TEST SETUP DIAGRAMS 
Figure 1.   General EUT Test Setup Diagram ....................................................................................................13
 
Figure 2.  Conducted Emissions Test Setup Diagram........................................................................................17
 
Figure 3.   Frequency ID of Radiated Emissions Test Setup Diagram...............................................................19
 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
Janurary 5,2006 
Harman Multimedia  OnStage UD    CE Test Report 
2006 011114 CE AUS/NZ 
 
4 of 72 
 
Figure 4.   Radiated Emissions Test Setup Diagram..........................................................................................21
 
Figure 5.   Harmonics & Flicker Test Setup Diagram........................................................................................24
 
Figure 6.   ESD Test Setup Diagram..................................................................................................................27
 
Figure 7.   Radio Frequency Immunity Test Setup Diagram .............................................................................29
 
Figure 8.   EFT Immunity Test Setup Diagram..................................................................................................31
 
Figure 9.   Power Line Surge Immunity Test Setup Diagram ............................................................................33
 
Figure 10.   RF Common Mode Immunity Test Setup Diagram........................................................................35
 
Figure 11.  Power Frequency Magnetic Field Immunity Test Setup .................................................................37
 
Figure 12.  Voltage Dips and Short Interruptions Test Setup Diagram .............................................................39
 
Figure 13.  ESD Test Points...............................................................................................................................46
 
TEST CONFIGURATION PHOTOGRAPHS 
Photograph 1.  General EUT Test Configuration...............................................................................................12
 
Photograph 2.  Conducted Emissions Test Configuration .................................................................................53
 
Photograph 3.  Radiated Emissions Test Configuration ....................................................................................54
 
Photograph 4.  ESD Test Configuration ............................................................................................................55
 
Photograph 5.  Radio Frequency Immunity Test Configuration ........................................................................56
 
Photograph 6.  EFT Immunity Test Configuration ............................................................................................57
 
Photograph 7.  Power Line Surge Immunity Test Configuration.......................................................................58
 
Photograph 8.  RF Common Mode Immunity Test Configuration ....................................................................59
 
Photograph 9.  Voltage Dips/Short Interruptions Test Configuration; Powerline Harmonics and Flicker Test 
Configuration .............................................................................................................................................60
 
APPENDICES 
A.
 
C
ONDUCTED 
&
 
R
ADIATED 
E
MISSIONS 
M
EASUREMENT 
U
NCERTAINTIES
........................................................ 61
 
B.
 
N
EMKO 
USA,
 
I
NC
.’
T
EST 
E
QUIPMENT 
&
 
F
ACILITIES 
C
ALIBRATION 
P
ROGRAM
............................................ 63
 
C.
 
NVLAP
 
A
CCREDITATION 
/
 
N
EMKO 
A
UTHORIZATION
..................................................................................... 65
 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
Janurary 5,2006 
Harman Multimedia  OnStage UD    CE Test Report 
2006 011114 CE AUS/NZ 
 
5 of 72 
 
 
CERTIFICATION 
 
The compatibility testing and this report have been prepared by Nemko USA, Inc., an independent 
electromagnetic compatibility consulting and test laboratory.   
 
Equipment. 
 
I certify the data evaluation and equipment configuration herein to be a true and accurate representation of the 
sample's immunity and emission characteristics, as of the test date(s), and for the design of the test sample 
utilized to compile this report. 
 
FR Fleury 
Chip Fleury 
Senior EMC Engineer 
 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
Janurary 5,2006 
Harman Multimedia  OnStage UD    CE Test Report 
2006 011114 CE AUS/NZ 
 
6 of 72 
 
1.  ADMINISTRATIVE DATA AND TEST SUMMARY 
1.1.  Administrative Data 
 
CLIENT: 
Harman Multimedia
 
8500 Balboa Blvd.
 
 
818 830-8764
 
 
CONTACT: 
Robert Tang
 
 
DATE (S) OF TEST: 
 January 3, 2005 to January 5, 2005   
 
EQUIPMENT UNDER TEST (EUT): 
Computer Speaker System
 
 
 
Model
 
OnStage UD
 
 
 
Condition Upon Receipt 
Suitable for Test 
 
TEST SPECIFICATION: 
Radio Frequency Emissions and Electromagnetic Immunity 
tests in accordance with requirements of EN 55022 (1998), 
A1(2000), A2(2003)  and EN 55024 (1998), A1(2001), 
A2(2003)  as follows: 
Test Type 
In Accordance with 
Document 
Document Title 
Conducted and 
Radiated Emissions 
EN 55022 (1998), 
A1(2000), A2(2003)  
Class ““B” 
Specifications for Limits and Methods of Measurement 
of Radio Disturbance Characteristics of Information 
Technology Equipment (ITE) 
Power Line Harmonics  
EN 61000-3-2 (2000), 
A1(2001), A2(2005)  
 
Electromagnetic Compatibility, Limits for Harmonic 
Current Emissions, Equipment Input Current 
less than 
or equal to
 16A 
Power Line Flicker  
EN 61000-3-3 (1995), 
A1(2001)  
Electromagnetic Compatibility, Limitation of Voltage 
Fluctuations and Flicker In Low-Voltage Supply 
Systems for Equipment with Rated Current 
less than or 
equal to
 16A 
Electrostatic Discharge 
Immunity 
IEC 61000-4-2 (2001)  
Electromagnetic Compatibility for Industrial Process 
Measurement and Control Equipment Electrostatic 
Discharge Requirements 
Radio Frequency 
Immunity 
IEC 61000-4-3 (2002)
 
 
Electromagnetic Compatibility, Basic Immunity 
Standard, Radiated Radio Frequency Electromagnetic 
Field, Immunity Test 
Electrical Fast 
Transient Burst 
Immunity 
IEC 61000-4-4 (2004)
 
 
Electromagnetic Compatibility for Industrial Process 
Measurement and Control Equipment Electrical Fast 
Transient / Burst Requirements 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
Janurary 5,2006 
Harman Multimedia  OnStage UD    CE Test Report 
2006 011114 CE AUS/NZ 
 
7 of 72 
 
Test Specifications Continued: 
Power Line Surge 
Immunity 
IEC 61000-4-5 (2001)
 
  
Electromagnetic Compatibility, Power Line Surge 
Immunity 
RF Common Mode 
Immunity 
IEC 61000-4-6 (2004)
 
  
Electromagnetic Compatibility - Basic Immunity Standard - 
Conducted Disturbances Induced By Radio-Frequency 
Fields - Immunity Test 
Power Frequency 
Magnetic Field 
IEC 61000-4-8 (2001)
 
   
Electromagnetic Compatibility, Testing and Measurement 
Techniques for Power Frequency Magnetic Field, 
Immunity Test 
Voltage Dips and Short 
Interruptions Immunity 
IEC 61000-4-11(2004)  
Electromagnetic Compatibility - Testing and Measurement 
Techniques - Voltage Dips, Short Interruptions and Voltage 
Variations Immunity Tests 
 
1.2.  Test Summary 
1.2.1. 
Emissions Test Summary 
 
Specification 
Frequency Range 
Compliance Status 
EN 55022 (1998), A1(2000), 
A2(2003) , Class “B
Conducted Emissions  
0.15 MHz – 30 MHz  
PASS  
EN 55022 (1998), A1(2000), 
A2(2003) , Class “B 
Telecom Conducted Emissions  
0.15 MHz – 30 MHz  
N/A 
EN 55022 (1998), A1(2000), 
A2(2003) , Class “B 
Radiated Emissions  
30 MHz – 1000 MHz  
PASS  
EN 61000-3-2 (2000), 
A1(2001), A2(2005)  
 
Power Line Harmonics 
up to the 40
th
 Harmonic 
Outside of Test 
Requirement 
EN 61000-3-3 (1995), 
A1(2001)  
Power Line Flicker 
less than or equal to
 4% Maximum Relative 
Voltage Change;  Value of D(T) 
less than or equal 
to
 3% for more than 200 Ms 
Outside of Test 
Requirement 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
Janurary 5,2006 
Harman Multimedia  OnStage UD    CE Test Report 
2006 011114 CE AUS/NZ 
 
8 of 72 
 
1.2.2. 
Immunity Test Summary 
 
 
Specification 
Minimum Criterion  
Level Required  
as per EN 55024  
 
Criterion Level 
Tested 
Compliance 
Status 
IEC 61000-4-2 (2001)  
- ESD Immunity 
Criterion B 
±8 kV air discharge,  
±4 kV contact discharge 
Criterion B 
±8 kV Air Discharge,  
±4 kV Contact Discharge 
PASS  
IEC 61000-4-3 (2002)
 
 -Radio Frequency 
Immunity 
Criterion A  
3 V/m from 80-1000 MHz  
(80% AM at 1kHz) 
Criterion A  
3 V/m from 80-1000 MHz  
(80% AM at 1kHz) 
PASS  
IEC 61000-4-4 (2004)
 
 
-Electrical Fast 
Transient Immunity 
Criterion B 
power line pulses of ± 1 kV; 
I/O line pulses of ± 0.5 kV 
Criterion B 
Power Line Pulses of ± 1 kV; 
up to ±2kV process/control lines; 
I/O Line Pulses of ± 0.5 kV 
PASS  
IEC 61000-4-5 (2001)
 
  
-Surge Immunity 
Criterion B 
±2kV common mode surges, 
±1kV differential mode surges 
Criterion C 
±2kV Common Mode Surges,  
±1kV Differential Mode Surges 
PASS  
IEC 61000-4-6 (2004)
 
  
-RF Common Mode 
Immunity 
Criterion A 
150 kHz - 80 MHz at 3 Vrms 
1 kHz 80% amplitude modulated 
Criterion A 
150 kHz - 80 MHz at 3 Vrms 
1kHz 80% amplitude modulated 
PASS  
IEC 61000-4-8 (2001)
 
  
 
Power Frequency 
Magnetic Field 
Criterion A 
Helmholtz coil at 50 Hz, 
to 30 amps (rms) per meter 
Criterion A 
Helmholtz coil at 50 Hz, 
to 30 amps (rms) per meter 
Outside of Test 
Requirement
 
IEC 61000-4-11(2004)  
- Voltage Dips and 
Short Interruptions 
Criterion B and C 
Voltage Dips of 30% and >95%; 
Interruptions of >95%. 
Criterion B and C 
Voltage Dips of 30% and >60%; 
Interruptions of >95%. 
PASS  
 
 
 
Test Supervisor
FR Fleury
 
Floyd Fleury, Nemko USA, Inc. 
Refer to the test results section for further details
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
Janurary 5,2006 
Harman Multimedia  OnStage UD    CE Test Report 
2006 011114 CE AUS/NZ 
 
9 of 72 
 
2.  SYSTEM CONFIGURATION 
2.1.  System Components and Power Cables 
 
 
 
DEVICE 
MANUFACTURER 
MODEL # 
SERIAL # 
 
POWER CABLE 
EUT - Computer Speaker 
System 
 
Harman Multimedia 
OnStage UD 
Serial #:  
N/A 
Support- Wall Wart Power 
Supply 
Leader Electronics Inc. 
MV20-11180-KOOF 
N/A 
1.5m, unshielded, 2 wire, 18 
AWG, DC jack 
Support-MP3 Player 
Apple I-Pod 
Mini 4GB 
JQ5205BBS43 
N/A 
 
 
 
2.2.  Device Interconnection and I/O Cables 
 
  
CONNECTION 
I/O CABLE 
No connections 
 
 
 
 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
Janurary 5,2006 
Harman Multimedia  OnStage UD    CE Test Report 
2006 011114 CE AUS/NZ 
 
10 of 72 
 
 
2.3.  Description and Method of Exercising the EUT 
 
The OnStage UD is a Computer Speaker System.  Its function is a cradle which provides auxiliary audio 
interface, computer interface, and battery recharging for the I-Pod. The EUT was exercised by playing music 
through the cradle speaker system.  It was monitored by listening to the audio output.  If the EUT audio 
operations are interrupted or degraded during immunity testing that would be considered a failure as they 
apply each immunity criteria.   
 
2.4.  Design Modifications for Compliance 
 
 
Device: Computer Speaker System 
Model:  OnStage UD 
 
No design modifications were made to the EUT during testing. 
 
 

Download JBL ON STAGEII (serv.man6) EMC - CB Certificate

Here you can view online and download JBL ON STAGEII (serv.man6) EMC - CB Certificate in PDF. ON STAGEII (serv.man6) emc - cb certificate will guide through the process and help you recover, restore, fix, disassemble and repair JBL ON STAGEII (serv.man6) Audio. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.