ON STAGEII (serv.man6) - JBL Audio EMC - CB Certificate (repair manual). Page 51

Read JBL ON STAGEII (serv.man6) EMC - CB Certificate online

Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
Janurary 5,2006 
Harman Multimedia  OnStage UD    CE Test Report 
2006 011114 CE AUS/NZ 
 
51 of 72 
 
4.7.  RF Conducted Common Mode Disturbance Immunity Test Results 
 
 
 
 
Client 
Harman Multimedia 
Temperature 70 
deg 
PAN # 
25-1114-HAR 
Relative Humidity 
49 
EUT Name 
Computer Speaker System 
Barometric Pressure 
30.5 
Hg 
EUT Model  
OnStage UD 
Test Location 
West Ground Plane 
Governing Doc 
EN 55024 
Test Engineer 
Rodel Resolme 
Basic Standard 
IEC 61000-4-6 
Date 
01/03/06 
 
 
Test Level: X 
3Vrms 
 
10Vrms 
 
 
Modulation: 
 
None (CW)  
X
80%AM @ 1kHz 
 
 
Frequency Range: X 
0.15 – 80 MHz   
0.15-230MHz 
 
 
Step: X 
1% 
 
10% 
 
1.5 x 10¯³ /decade 
Performance Criteria: X 
 
 
 
 
 
 
Injection Point (Cable)  Leader P/S Mains 
Injection Method:  
Clamp 
X  CDN 
Comments:  
Injection Point (Cable) 
 
Injection Method:  
Clamp 
 
CDN 
Comments:  
Injection Point (Cable) 
 
Injection Method:  
Clamp 
 
CDN 
Comments:  
Injection Point (Cable) 
 
Injection Method:  
 
 
 
Comments:  
Injection Point (Cable) 
 
Injection Method:  
 
 
 
Comments:  
 
 
 
 
 
Test Equipment Used 
 
Asset # 
X if Used Calibration 
Done Calibration 
Due 
HP 8462B  (Signal Generator) 
751 
1/6/05 
1/6/06 
Fluke 6060B  (Signal Generator) 
212 
 
 
 
HP 8648B  (Signal Generator) 
746 
 
 
 
FCC-801-M1-25  (CDN) 
473 
 
 
 
FCC-801-M2-25  (CDN) 
472 
 
 
 
FCC-801-M3-25  (CDN) 
466 
3/14/05 
3/14/06 
FCC-801-M4-25  (CDN) 
628 
 
 
 
FCC-801-M5-25  (CDN) 
629 
 
 
 
FCC-801-T2  (CDN) 
626 
 
 
 
FCC-801-T4  (CDN) 
627 
 
 
 
AR 10A250  (Amplifier) 
402 
 
NCR 
NCR 
IFI 1500  (Amplifier) 
571 
 
NCR 
NCR 
RF Power Labs  (Amplifier) 
397 
 
NCR 
NCR 
Solar 9144-1N  (Clamp) 
436 
 
 
 
Solar 9121-1N  (Clamp) 
435 
 
 
 
Solar 6741-1N  (Clamp) 
144 
 
 
 
 
 
 
 
 
Compliant    X   
Non-Compliant 
 
 
Photo X 
 
 
Page of 72
Display