Read JBL ON STAGEII (serv.man6) EMC - CB Certificate online
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
Janurary 5,2006
Harman Multimedia OnStage UD CE Test Report
2006 011114 CE AUS/NZ
51 of 72
4.7. RF Conducted Common Mode Disturbance Immunity Test Results
Client
Harman Multimedia
Temperature 70
deg
F
PAN #
25-1114-HAR
Relative Humidity
49
%
EUT Name
Computer Speaker System
Barometric Pressure
30.5
Hg
EUT Model
OnStage UD
Test Location
West Ground Plane
Governing Doc
EN 55024
Test Engineer
Rodel Resolme
Basic Standard
IEC 61000-4-6
Date
01/03/06
Test Level: X
3Vrms
10Vrms
Modulation:
None (CW)
X
80%AM @ 1kHz
Frequency Range: X
0.15 – 80 MHz
0.15-230MHz
Step: X
1%
10%
1.5 x 10¯³ /decade
Performance Criteria: X
A
B
1
Injection Point (Cable) Leader P/S Mains
Injection Method:
Clamp
X CDN
Comments:
2
Injection Point (Cable)
Injection Method:
Clamp
CDN
Comments:
3
Injection Point (Cable)
Injection Method:
Clamp
CDN
Comments:
4
Injection Point (Cable)
Injection Method:
Comments:
5
Injection Point (Cable)
Injection Method:
Comments:
Test Equipment Used
Asset #
X if Used Calibration
Done Calibration
Due
HP 8462B (Signal Generator)
751
X
1/6/05
1/6/06
Fluke 6060B (Signal Generator)
212
HP 8648B (Signal Generator)
746
FCC-801-M1-25 (CDN)
473
FCC-801-M2-25 (CDN)
472
FCC-801-M3-25 (CDN)
466
X
3/14/05
3/14/06
FCC-801-M4-25 (CDN)
628
FCC-801-M5-25 (CDN)
629
FCC-801-T2 (CDN)
626
FCC-801-T4 (CDN)
627
AR 10A250 (Amplifier)
402
NCR
NCR
IFI 1500 (Amplifier)
571
NCR
NCR
RF Power Labs (Amplifier)
397
NCR
NCR
Solar 9144-1N (Clamp)
436
Solar 9121-1N (Clamp)
435
Solar 6741-1N (Clamp)
144
Compliant X
Non-Compliant
Photo X
Click on the first or last page to see other ON STAGEII (serv.man6) service manuals if exist.