ON STAGEII (serv.man6) - JBL Audio EMC - CB Certificate (repair manual). Page 49

Read JBL ON STAGEII (serv.man6) EMC - CB Certificate online

Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
Janurary 5,2006 
Harman Multimedia  OnStage UD    CE Test Report 
2006 011114 CE AUS/NZ 
 
49 of 72 
 
4.5.  Electrical Fast Transient Burst Immunity Test Results 
Client 
Harman Multimedia 
Temperature 70 
deg 
PAN # 
25-1114-HAR 
Relative Humidity 
49 
EUT Name 
Computer Speaker System 
Barometric Pressure 
30.5 
Hg 
EUT Model  
OnStage UD 
Test Location 
Location 
Governing Doc 
EN 55024 
Test Engineer 
Test Technician 
Basic Standard 
IEC 61000-4-4 
Date 
01/03/06 
Test Level: 
 
 
 
 
AC / DC Mains / Control Ports 
 
0.5kV 
X  1.0kV 
 
2.0kV 
 
4.0kV 
 
______ 
Signal 
Ports 
 0.25kV   0.5kV   1.0kV 
 2.0kV  ______ 
 
 
 
 
 
Test Duration: 
X 61 
sec 
  _______ 
 
 
 
 
 
 
 
Test Equipment  
 
Asset # Used Calibration 
Done Calibration 
Due 
EMC Partner 2000 
845 
10/30/05 
02/28/06 
Haefely 093 506.1 Clamp 
417 
 
NCR 
NCR 
Haefely FP-EFT Generator 32.1 
689 
 
 
 
Noiseken FNS-100L 
547 
 
 
 
Noiseken 15-00001A Clamp 
802 
 
NCR 
NCR 
 
 
 
 
Performance Criteria: 
X  
 
 
 
Direct Injection Output Path 
Test Level 
Polarity 
(+/-) 
L1 L2 PE 
Comments 
1.0kV 
+/- 
 
 
Burst noise heard on speakers during test. Î PASS 
 1.0kV 
+/- 
 
 
Burst noise heard on speakers during test. Î PASS 
1.0kV 
+/- 
 
Burst noise heard on speakers during test. Î PASS 
Cable Description (Clamp Injection) Polarity 
 
 
 
 
Compliant   X 
 
Non-Compliant  
 
 
Photo  
X   
 
Page of 72