National Differences
Clause
Requirement − Test
Result – Remark
Verdict
Australian National Differences according to CB Bulletin No. CB Bulletin No. 109A, December 2005
chosen to ensure adequacy of the insulation
concerned and does not necessarily simulate
likely overvoltages.
concerned and does not necessarily simulate
likely overvoltages.
6.2.2.2
Delete the note.
Add the following after the second paragraph:
In Australia (this variation does not apply in New
Zealand), the a.c. test voltage is:
Zealand), the a.c. test voltage is:
- for 6.2.1a):
3 kV; and
- for 6.2.1b) and 6.2.1c):
1.5 kV.
NOTE 201 – Where there are capacitors across
the insulation under test, it is recommended that
d.c. test voltages are used.
the insulation under test, it is recommended that
d.c. test voltages are used.
NOTE 202 – The 3 kV and 1.5 kV values have
been determined considering the low frequency
induced voltages from the power supply
distribution system.
been determined considering the low frequency
induced voltages from the power supply
distribution system.
No TNV.
N/A
Annex P
Add the following Normative References to Annex
P:
P:
IEC 60065, Audio, Video and similar electronic
apparatus - Safety requirements
apparatus - Safety requirements
AS/NZS 3112, Approval and test specification -
Plugs and socket-outlets
Plugs and socket-outlets
AS/NZS 3191, Approval and test specification -
Electric flexible cords
Electric flexible cords
AS/NZS 4695.707, Fire hazard testing of
electrotechnical products - Methods of test for the
determination of the flammability of solid electrical
insulating materials when exposed to an igniting
source
electrotechnical products - Methods of test for the
determination of the flammability of solid electrical
insulating materials when exposed to an igniting
source
Added.
P