ON STAGE III IIIP (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 58

Read JBL ON STAGE III IIIP (serv.man2) EMC - CB Certificate online

 
 
<12014238 001 > 
 
 
Page 57 of 77 
 
National Differences 
Clause 
Requirement − Test 
Result – Remark 
Verdict 
 
Australian National Differences according to CB Bulletin No. CB Bulletin No. 109A, December 2005  
 
chosen to ensure adequacy of the insulation 
concerned and does not necessarily simulate 
likely overvoltages.  
6.2.2.2 
Delete the note. 
Add the following after the second paragraph: 
In Australia (this variation does not apply in New 
Zealand), the a.c. test voltage is:  
- for 6.2.1a): 
 
 
3 kV; and  
- for 6.2.1b) and 6.2.1c): 
1.5 kV.  
NOTE 201 – Where there are capacitors across 
the insulation under test, it is recommended that 
d.c. test voltages are used.  
NOTE 202 – The 3 kV and 1.5 kV values have 
been determined considering the low frequency 
induced voltages from the power supply 
distribution system.  
No TNV. 
N/A 
Annex P 
Add the following Normative References to Annex 
P: 
IEC 60065, Audio, Video and similar electronic 
apparatus - Safety requirements 
AS/NZS 3112, Approval and test specification - 
Plugs and socket-outlets  
AS/NZS 3191, Approval and test specification - 
Electric flexible cords 
AS/NZS 4695.707, Fire hazard testing of 
electrotechnical products - Methods of test for the 
determination of the flammability of solid electrical 
insulating materials when exposed to an igniting 
source 
Added. 
 
 
 
Page of 78