National Differences 
Clause 
Requirement − Test 
Result – Remark 
Verdict 
 
Japanese National Differences according to CB Bulletin No. CB Bulletin No. 109A, December 2005  
 
NOTE 2 - Similarly, other MATERIALS, including 
rigid (engineering structural) foam of CLASSES 
5V or V-0 are regarded as better than those of 
CLASS V-1, V-1 better than V-2, and V-2 better 
than HB. 
NOTE 3 - Similarly, for thin MATERIALS, VTM-0 
Class materials are regarded as better than those 
of VTM-1 Class, and VTM-1 better than VTM-2. 
1.2.12.101  Addition: 
VTM CLASS MATERIAL: Thin MATERIALS fulfil 
the specified conditions during the test of clause 
A.101 applied for materials that the test and 
evaluation of clauses A.6 to A.10 is difficult to 
enforce. Materials are classified to three 
classifications as VTM-0, VTM-1 and VTM-2 
according to the conditions after the removal of 
the test flame. 
Added. 
N/A 
1.7.101 
Addition: 
Marking for CLASS 0I EQUIPMENT 
For CLASS 0I EQUIPMENT, the following 
instruction shall be indicated on the visible place 
of the mains plug or the main body: 
“Provide an earthing connection”  
Moreover, for CLASS 0I EQUIPMENT, the 
following instruction shall be indicated on the 
visible place of the main body or written in the 
operating instructions: 
“Provide an earthing connection before the mains 
plug is connected to the mains. And, when 
disconnecting the earthing connection, be sure to 
disconnect after pulling out the mains plug from 
the mains.” 
Added. 
N/A 
2.1.1.1 
Replacement: 
Replace “IEC 60083” to “IEC 60083 or JIS C 
8303” in 2.1.1.1 b). 
Replaced. 
2.6.3.1 
Addition: 
Add the following after 1st paragraph. 
This also applies to the conductor of lead wire for 
protective earthing of CLASS 0I EQUIPMENT. 
Added. 
N/A 
2.6.4.1 
Replacement: 
Replace 2nd sentence in 1st paragraph. 
For CLASS I EQUIPMENT with a DETACHABLE 
POWER SUPPLY CORD, the earthing terminal in 
the appliance inlet is regarded as the main 
protective earthing terminal. 
Replaced. 
N/A 