National Differences
Clause
Requirement − Test
Result – Remark
Verdict
Japanese National Differences according to CB Bulletin No. CB Bulletin No. 109A, December 2005
NOTE 2 - Similarly, other MATERIALS, including
rigid (engineering structural) foam of CLASSES
5V or V-0 are regarded as better than those of
CLASS V-1, V-1 better than V-2, and V-2 better
than HB.
rigid (engineering structural) foam of CLASSES
5V or V-0 are regarded as better than those of
CLASS V-1, V-1 better than V-2, and V-2 better
than HB.
NOTE 3 - Similarly, for thin MATERIALS, VTM-0
Class materials are regarded as better than those
of VTM-1 Class, and VTM-1 better than VTM-2.
Class materials are regarded as better than those
of VTM-1 Class, and VTM-1 better than VTM-2.
1.2.12.101 Addition:
VTM CLASS MATERIAL: Thin MATERIALS fulfil
the specified conditions during the test of clause
A.101 applied for materials that the test and
evaluation of clauses A.6 to A.10 is difficult to
enforce. Materials are classified to three
classifications as VTM-0, VTM-1 and VTM-2
according to the conditions after the removal of
the test flame.
the specified conditions during the test of clause
A.101 applied for materials that the test and
evaluation of clauses A.6 to A.10 is difficult to
enforce. Materials are classified to three
classifications as VTM-0, VTM-1 and VTM-2
according to the conditions after the removal of
the test flame.
Added.
N/A
1.7.101
Addition:
Marking for CLASS 0I EQUIPMENT
For CLASS 0I EQUIPMENT, the following
instruction shall be indicated on the visible place
of the mains plug or the main body:
instruction shall be indicated on the visible place
of the mains plug or the main body:
“Provide an earthing connection”
Moreover, for CLASS 0I EQUIPMENT, the
following instruction shall be indicated on the
visible place of the main body or written in the
operating instructions:
following instruction shall be indicated on the
visible place of the main body or written in the
operating instructions:
“Provide an earthing connection before the mains
plug is connected to the mains. And, when
disconnecting the earthing connection, be sure to
disconnect after pulling out the mains plug from
the mains.”
plug is connected to the mains. And, when
disconnecting the earthing connection, be sure to
disconnect after pulling out the mains plug from
the mains.”
Added.
N/A
2.1.1.1
Replacement:
Replace “IEC 60083” to “IEC 60083 or JIS C
8303” in 2.1.1.1 b).
8303” in 2.1.1.1 b).
Replaced.
P
2.6.3.1
Addition:
Add the following after 1st paragraph.
This also applies to the conductor of lead wire for
protective earthing of CLASS 0I EQUIPMENT.
protective earthing of CLASS 0I EQUIPMENT.
Added.
N/A
2.6.4.1
Replacement:
Replace 2nd sentence in 1st paragraph.
For CLASS I EQUIPMENT with a DETACHABLE
POWER SUPPLY CORD, the earthing terminal in
the appliance inlet is regarded as the main
protective earthing terminal.
POWER SUPPLY CORD, the earthing terminal in
the appliance inlet is regarded as the main
protective earthing terminal.
Replaced.
N/A