National Differences
Clause
Requirement − Test
Result – Remark
Verdict
Australian National Differences according to CB Bulletin No. CB Bulletin No. 109A, December 2005
Over 3 up to and
including 7.5
including 7.5
0.75
16 [1.3]
Over 7.5 up to
and including 10
and including 10
(0.75)
2)
1.00
16 [1.3]
Over 10 up to
and including 16
and including 16
(1.0)
3)
1.5
14 [2]
Replace footnote 1) with the following:
1)
This nominal cross-sectional area is only
allowed for Class II appliances if the length of the
power supply cord, measured between the point
where the cord, or cord guard, enters the
appliances, and the entry to the plug does not
exceed 2 m (0.5 mm² three-core supply flexible
cords are not permitted; see AS/NZS 3191).
power supply cord, measured between the point
where the cord, or cord guard, enters the
appliances, and the entry to the plug does not
exceed 2 m (0.5 mm² three-core supply flexible
cords are not permitted; see AS/NZS 3191).
Delete Note 1.
4.3.6
Replace paragraph three with:
Equipment with a plug portion, suitable for
insertion into a 10 A 3-pin flat-pin socket-outlet
complying with AS/NZS 3112, shall comply with
the requirements in AS/NZS 3112 for equipment
with integral pins for insertion into socket-outlets.
insertion into a 10 A 3-pin flat-pin socket-outlet
complying with AS/NZS 3112, shall comply with
the requirements in AS/NZS 3112 for equipment
with integral pins for insertion into socket-outlets.
Replaced.
N/A
4.3.13.5
Add the following to the end of the first paragraph:
", or AS/NZS 2211.1"
Added.
P
4.7
Add the following paragraph:
For alternative tests refer to clause 4.7.201.
Added.
P
4.7.201
Add the following after clause 4.7.3.6:
4.7.201 Resistance to fire - Alternative tests
Added.
P
4.7.201.1
General
Parts of non-metallic material shall be resistant to
ignition and spread of fire.
ignition and spread of fire.
This requirement does not apply to decorative
trims, knobs and other parts unlikely to be ignited
or to propagate flames originating from inside the
apparatus, or the following:
trims, knobs and other parts unlikely to be ignited
or to propagate flames originating from inside the
apparatus, or the following:
(a) Components that are contained in an
enclosure having a flammability category of
FV-0 according to AS/NSZ 4695.707 and
having openings only for the connecting wires
filling the openings completely, and for the
ventilation not exceeding 1 mm in width
regardless of the length.
FV-0 according to AS/NSZ 4695.707 and
having openings only for the connecting wires
filling the openings completely, and for the
ventilation not exceeding 1 mm in width
regardless of the length.
(b) The following parts which would contribute
negligible fuel to a fire:
Enclosure, PCB, bobbin
P