ON STAGE III IIIP (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 53

Read JBL ON STAGE III IIIP (serv.man2) EMC - CB Certificate online

 
 
<12014238 001 > 
 
 
Page 52 of 77 
 
National Differences 
Clause 
Requirement − Test 
Result – Remark 
Verdict 
 
Australian National Differences according to CB Bulletin No. CB Bulletin No. 109A, December 2005  
 
Over 3 up to and 
including 7.5 
0.75 
16 [1.3] 
Over 7.5 up to 
and including 10 
(0.75)
2)
 1.00 
16 [1.3] 
Over 10 up to 
and including 16 
(1.0)
3)
 1.5 
14 [2] 
Replace footnote 1) with the following: 
1)
  This  nominal  cross-sectional  area  is  only 
allowed for Class II appliances if the length of the 
power  supply  cord,  measured  between  the  point 
where  the  cord,  or  cord  guard,  enters  the 
appliances,  and  the  entry  to  the  plug  does  not 
exceed  2  m  (0.5  mm²  three-core  supply  flexible 
cords are not permitted; see AS/NZS 3191).  
Delete Note 1. 
4.3.6 
Replace paragraph three with:  
Equipment with a plug portion, suitable for 
insertion into a 10 A 3-pin flat-pin socket-outlet 
complying with AS/NZS 3112, shall comply with 
the requirements in AS/NZS 3112 for equipment 
with integral pins for insertion into socket-outlets.  
Replaced. 
N/A 
4.3.13.5 
Add the following to the end of the first paragraph:  
", or AS/NZS 2211.1"  
Added. 
4.7 
Add the following paragraph: 
For alternative tests refer to clause 4.7.201.  
Added.  
4.7.201 
Add the following after clause 4.7.3.6: 
4.7.201 Resistance to fire - Alternative tests 
Added.  
4.7.201.1 
General 
Parts of non-metallic material shall be resistant to 
ignition and spread of fire. 
This requirement does not apply to decorative 
trims, knobs and other parts unlikely to be ignited 
or to propagate flames originating from inside the 
apparatus, or the following: 
(a)  Components that are contained in an 
enclosure having a flammability category of 
FV-0 according to AS/NSZ 4695.707 and 
having openings only for the connecting wires 
filling the openings completely, and for the 
ventilation not exceeding 1 mm in width 
regardless of the length. 
(b)  The following parts which would contribute 
negligible fuel to a fire: 
Enclosure, PCB, bobbin 
Page of 78
Display