Read JBL ON STAGE III IIIP (serv.man2) EMC - CB Certificate online
<12014238 001 >
Page 61 of 77
National Differences
Clause
Requirement − Test
Result – Remark
Verdict
Japanese National Differences according to CB Bulletin No. CB Bulletin No. 109A, December 2005
4.7.3.2
Addition:
Add the following in 7th paragraph.
for thin materials, e.g., flexible printed boards,
etc., used inside equipment, be of
FLAMMABILITY CLASS VTM-2 or better.
etc., used inside equipment, be of
FLAMMABILITY CLASS VTM-2 or better.
Added.
N/A
Replacement:
Replace Table 5A.
Type of equipment
Terminal A of
measuring instrument
connected to:
measuring instrument
connected to:
Maximum
TOUCH
CURRENT
CURRENT
mA r.m.s.
1)
Maximum
PROTECTIVE
CONDUCTOR
CURRENT
CONDUCTOR
CURRENT
ALL equipment
Accessible parts and
circuits not connected
to protective earth
circuits not connected
to protective earth
0.25
−
HAND-HELD
0.75
−
MOVABLE (other
than HAND_HELD,
but including
TRANSPORTABLE
EQUIPMENT
than HAND_HELD,
but including
TRANSPORTABLE
EQUIPMENT
3.5
−
STATIONARY,
PLUGGABLE TYPE
A
PLUGGABLE TYPE
A
3.5
−
ALL other
STATIONARY
EQUIPMENT
STATIONARY
EQUIPMENT
not subject to the
conditions of 5.1.7
conditions of 5.1.7
3.5
−
subject to the
conditions of 5.1.7
conditions of 5.1.7
Equipment main
protective earthing
terminal (if any)
protective earthing
terminal (if any)
CLASS I
EQUIPMENT
EQUIPMENT
−
5 % of input
current
current
HAND-HELD
Equipment main
protective earthing
terminal (if any)
protective earthing
terminal (if any)
CLASS 0I
EQUIPMENT
EQUIPMENT
0.5
−
Others
1.0
−
5.1.6
1)
If peak values of TOUCH-CURRENT are measured, the maximum values
obtained by multiplying the r.m.s. values by 1.414.