ON STAGE III IIIP (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 62

Read JBL ON STAGE III IIIP (serv.man2) EMC - CB Certificate online

 
 
<12014238 001 > 
 
 
Page 61 of 77 
 
National Differences 
Clause 
Requirement − Test 
Result – Remark 
Verdict 
 
Japanese National Differences according to CB Bulletin No. CB Bulletin No. 109A, December 2005  
 
4.7.3.2 
Addition: 
Add the following in 7th paragraph. 
for thin materials, e.g., flexible printed boards, 
etc., used inside equipment, be of 
FLAMMABILITY CLASS VTM-2 or better. 
Added. 
N/A 
Replacement:  
Replace Table 5A. 
Type of equipment 
Terminal A of 
measuring instrument 
connected to: 
Maximum 
TOUCH 
CURRENT 
mA r.m.s. 
1)
 
Maximum 
PROTECTIVE 
CONDUCTOR 
CURRENT 
ALL equipment 
Accessible parts and 
circuits not connected 
to protective earth 
0.25 
− 
HAND-HELD 
0.75 
− 
MOVABLE (other 
than HAND_HELD, 
but including 
TRANSPORTABLE 
EQUIPMENT 
3.5 
− 
STATIONARY, 
PLUGGABLE TYPE 
3.5 
− 
ALL other 
STATIONARY 
EQUIPMENT 
 
 
not subject to the 
conditions of 5.1.7 
3.5 
− 
subject to the 
conditions of 5.1.7 
Equipment main 
protective earthing 
terminal (if any) 
CLASS I 
EQUIPMENT 
− 
5 % of input 
current 
HAND-HELD 
Equipment main 
protective earthing 
terminal (if any)  
CLASS 0I 
EQUIPMENT 
0.5 
− 
Others 
 
1.0 
− 
5.1.6 
1)
 If peak values of TOUCH-CURRENT are measured, the maximum values 
obtained by multiplying the r.m.s. values by 1.414. 