IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
2.6.5.4
Parts that can be removed by an operator
N/A
2.6.5.5
Parts removed during servicing
N/A
2.6.5.6
Corrosion resistance
N/A
2.6.5.7
Screws for protective bonding
N/A
2.6.5.8
Reliance on telecommunication network or cable
distribution system
distribution system
No TNV
N/A
2.7
Overcurrent and earth fault protection in primary circuits
P
2.7.1
Basic requirements
Equipment relies on 16A rated
fuse or circuit breaker of the wall
outlet installation protection of
the building installation in regard
to L to N short circuit.
Overcurrent protection is
provided by the current fuse.
fuse or circuit breaker of the wall
outlet installation protection of
the building installation in regard
to L to N short circuit.
Overcurrent protection is
provided by the current fuse.
P
Instructions when protection relies on building
installation
installation
Not applicable for pluggable
equipment type A.
equipment type A.
N/A
2.7.2
Faults not covered in 5.3
The protection device is well
dimensioned and mounted.
dimensioned and mounted.
P
2.7.3
Short-circuit backup protection
Pluggable equipment type A.
Building installation is
considered as providing short-
circuit backup protection.
Building installation is
considered as providing short-
circuit backup protection.
P
2.7.4
Number and location of protective devices ..........: Over current protection by one
built-in current fuse.
P
2.7.5
Protection by several devices
Only one current fuse provided.
N/A
2.7.6
Warning to service personnel ...............................: No service work is necessary.
N/A
2.8
Safety interlocks
N/A
2.8.1
General principles
No safety interlock.
N/A
2.8.2
Protection requirements
N/A
2.8.3
Inadvertent reactivation
N/A
2.8.4
Fail-safe operation
N/A
2.8.5
Moving parts
N/A
2.8.6
Overriding
N/A
2.8.7
Switches and relays
N/A
2.8.7.1
Contact gaps (mm) ..............................................:
N/A
2.8.7.2
Overload test
N/A
2.8.7.3
Endurance test
N/A
2.8.7.4
Electric strength test
N/A