IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
2.2.3 
Voltages under fault conditions (V).......................:  Single fault did not cause 
excessive voltage in accessible 
SELV circuits. Limits of 71V 
peak and 120V d.c. were not 
exceeded within 0.2 seconds 
and limits 42.4V peak and 60V 
d.c. were not exceeded for 
longer than 0.2 seconds. 
2.2.3.1 
Separation by double insulation or reinforced 
insulation (method 1) 
Double or reinforced for the 
highest working voltage across 
a particular insulation is 
provided. 
2.2.3.2 
Separation by earthed screen (method 2) 
 
N/A 
2.2.3.3 
Protection by earthing of the SELV circuit 
(method 3) 
 
N/A 
2.2.4 
Connection of SELV circuits to other circuits........:  See 2.2.2 and 2.2.3. 
 
2.3 
TNV circuits 
N/A 
2.3.1 
Limits 
No TNV. 
N/A 
 
Type of TNV circuits .............................................:   
 
2.3.2 
Separation from other circuits and from accessible 
parts 
 
N/A 
 
Insulation employed ..............................................:   
 
2.3.3 
Separation from hazardous voltages 
 
N/A 
 
Insulation employed ..............................................:   
 
2.3.4 
Connection of TNV circuits to other circuits 
 
N/A 
 
Insulation employed ..............................................:   
 
2.3.5 
Test for operating voltages generated externally 
 
N/A 
 
2.4 
Limited current circuits 
N/A 
2.4.1 
General requirements 
 
N/A 
2.4.2 
Limit values 
 
N/A 
 
Frequency (Hz) .....................................................:   
 
 
Measured current (mA).........................................:   
 
 
Measured voltage (V) ...........................................:   
 
 
Measured capacitance (µF) ..................................:   
 
2.4.3 
Connection of limited current circuits to other 
circuits 
 
N/A 
 
 
 
 
2.5 
Limited power sources 