IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
1.6.2
Input current
Highest load according to
1.2.2.1 for this equipment is the
operation with the max.
specified DC-load.
1.2.2.1 for this equipment is the
operation with the max.
specified DC-load.
Results see appended table
P
1.6.3
Voltage limit of hand-held equipment
Not hand-held equipment.
N/A
1.6.4
Neutral conductor
Class II equipment without earth
connection.
connection.
N/A
1.7
Marking and instructions
P
1.7.1
Power rating
See below.
P
Rated voltage(s) or voltage range(s) (V) .............: AC100-240V
P
Symbol for nature of supply, for d.c. only .............: Mains from AC source
N/A
Rated frequency or rated frequency range (Hz) ..: 50/60Hz
P
Rated current (mA or A) ......................................: 0.7A
P
Manufacturer’s name or trademark or identification
mark .....................................................................:
mark .....................................................................:
Not shown / trademark of DVE
P
Type/model or type reference...............................: DSA-20R-12 Fa xy
P
Symbol for Class II equipment only .....................: Double square symbol
provided.
P
Other symbols ......................................................: Additional symbols or marking
does not give rise to
misunderstanding.
misunderstanding.
P
Certification marks ...............................................: Refer to the copy of the label
drawings for details.
P
1.7.2
Safety instructions
"User's Manual" provided that
contains information regarding
the maximum ambient
temperature.
contains information regarding
the maximum ambient
temperature.
P
1.7.3
Short duty cycles
Equipment is designed for
continuous operation.
continuous operation.
N/A
1.7.4
Supply voltage adjustment ...................................: No voltage selector.
N/A
Methods and means of adjustment; reference to
installation instructions .........................................:
installation instructions .........................................:
N/A
1.7.5
Power outlets on the equipment ..........................: No power outlets provided.
N/A
1.7.6
Fuse identification (marking, special fusing
characteristics, cross-reference) .........................:
characteristics, cross-reference) .........................:
Marking adjacent to fuse on
PCB as:
PCB as:
F1 T1AL 250VAC
P
1.7.7
Wiring terminals
See below.
N/A
1.7.7.1
Protective earthing and bonding terminals ..........: Class II equipment without earth
connection.
N/A