ON STAGE III IIIP (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 10

Read JBL ON STAGE III IIIP (serv.man2) EMC - CB Certificate online

 
 
<12014238 001 > 
 
 
Page 9 of 77 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
2.1.1 
Protection in operator access areas  
No access with test finger and 
test pin to any parts with only 
basic insulation to ELV or 
hazardous voltage. 
2.1.1.1 
Access to energized parts 
See above. 
 
Test by inspection ................................................:  See above. 
 
Test with test finger ..............................................:  See above. 
 
Test with test pin ..................................................:  See above. 
 
Test with test probe  .............................................:  No TNV. 
N/A 
2.1.1.2 
Battery compartments  .........................................:  No battery compartment. 
N/A 
2.1.1.3 
Access to ELV wiring 
No ELV wiring in operator 
accessible area. 
N/A 
 
Working voltage (Vpeak or Vrms); minimum 
distance (mm) through insulation 
(see appended table 2.10.5) 
 
2.1.1.4 
Access to hazardous voltage circuit wiring 
No hazardous voltage wiring in 
operator accessible area. 
N/A 
2.1.1.5 
Energy hazards ....................................................:  Energy does not exceed 240VA 
between any two points in 
accessible parts (o/p connector 
of secondary circuit). Results 
see appended table 2.1.1.5. No 
energy hazard in operator 
access area. 
2.1.1.6 
Manual controls 
No manual controls. 
N/A 
2.1.1.7 
Discharge of capacitors in equipment 
There is no capacitor connected 
to the mains circuit. 
N/A 
 
Time-constant (s); measured voltage (V) .............:   
 
2.1.2 
Protection in service access areas 
No operator accessible area 
that needs to be accessed by 
the use of a tool. 
N/A 
2.1.3 
Protection in restricted access locations 
Not limited for use in restricted 
access locations. 
N/A 
 
2.2 
SELV circuits 
2.2.1 
General requirements 
The secondary circuits were 
tested as SELV. See 2.2.1 to 
2.2.4. 
2.2.2 
Voltages under normal conditions (V) ..................:  Between any conductor of the 
SELV circuits 42.4 V peak or 
60 V d.c. are not exceeded.      
See appended table 2.2.2. 