IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
2.1.1
Protection in operator access areas
No access with test finger and
test pin to any parts with only
basic insulation to ELV or
hazardous voltage.
test pin to any parts with only
basic insulation to ELV or
hazardous voltage.
P
2.1.1.1
Access to energized parts
See above.
P
Test by inspection ................................................: See above.
P
Test with test finger ..............................................: See above.
P
Test with test pin ..................................................: See above.
P
Test with test probe .............................................: No TNV.
N/A
2.1.1.2
Battery compartments .........................................: No battery compartment.
N/A
2.1.1.3
Access to ELV wiring
No ELV wiring in operator
accessible area.
accessible area.
N/A
Working voltage (Vpeak or Vrms); minimum
distance (mm) through insulation
distance (mm) through insulation
(see appended table 2.10.5)
2.1.1.4
Access to hazardous voltage circuit wiring
No hazardous voltage wiring in
operator accessible area.
operator accessible area.
N/A
2.1.1.5
Energy hazards ....................................................: Energy does not exceed 240VA
between any two points in
accessible parts (o/p connector
of secondary circuit). Results
see appended table 2.1.1.5. No
energy hazard in operator
access area.
accessible parts (o/p connector
of secondary circuit). Results
see appended table 2.1.1.5. No
energy hazard in operator
access area.
P
2.1.1.6
Manual controls
No manual controls.
N/A
2.1.1.7
Discharge of capacitors in equipment
There is no capacitor connected
to the mains circuit.
to the mains circuit.
N/A
Time-constant (s); measured voltage (V) .............:
2.1.2
Protection in service access areas
No operator accessible area
that needs to be accessed by
the use of a tool.
that needs to be accessed by
the use of a tool.
N/A
2.1.3
Protection in restricted access locations
Not limited for use in restricted
access locations.
access locations.
N/A
2.2
SELV circuits
P
2.2.1
General requirements
The secondary circuits were
tested as SELV. See 2.2.1 to
2.2.4.
tested as SELV. See 2.2.1 to
2.2.4.
P
2.2.2
Voltages under normal conditions (V) ..................: Between any conductor of the
SELV circuits 42.4 V peak or
60 V d.c. are not exceeded.
60 V d.c. are not exceeded.
See appended table 2.2.2.
P