ON STAGE III IIIP (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 7

Read JBL ON STAGE III IIIP (serv.man2) EMC - CB Certificate online

 
 
<12014238 001 > 
 
 
Page 6 of 77 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
  
GENERAL 
1.5 
Components 
1.5.1 
General 
Components which were found 
to affect safety aspects comply 
with the requirements of this 
standard or within the safety 
aspects of the relevant IEC 
component standards. 
 
Comply with IEC 60950 or relevant component 
standard  
(see appended table 1.5.1) 
1.5.2 
Evaluation and testing of components 
Components which are certified 
to IEC and /or national 
standards are used correctly 
within their ratings. 
Components not covered by 
IEC standards are tested under 
the conditions present in the 
equipment. 
1.5.3 
Thermal controls 
No thermal controls provided. 
N/A 
1.5.4 
Transformers 
Transformer used are suitable 
for their intended application 
and comply with the relevant 
requirements of the standard 
and particularly Annex C. 
1.5.5 
Interconnecting cables 
Interconnection o/p cable to 
other device is carrying only 
SELV on an energy level below 
240 VA. 
→ Except for the insulation 
material, there are no further 
requirements for the o/p 
interconnection cable. 
1.5.6 
Capacitors in primary circuits ...............................:  No X capacitor provided. 
N/A 
1.5.7 
Double insulation or reinforced insulation bridged 
by components 
See below. 
N/A 
1.5.7.1 
General 
 
N/A 
1.5.7.2 
Bridging capacitors 
No bridging capacitor used. 
N/A 
1.5.7.3 
Bridging resistors 
No bridging resistor used. 
N/A 
1.5.7.4 
Accessible parts 
See clause 2.4 
N/A 
1.5.8 
Components in equipment for IT power systems 
No such component 
N/A 
 
 
 
 
1.6 
Power interface 
1.6.1 
AC power distribution systems 
IT power system for Norway 
only, TN power system for 
others  
Page of 78