ON STAGE 200ID (serv.man3) - JBL Audio EMC - CB Certificate (repair manual). Page 35

Read JBL ON STAGE 200ID (serv.man3) EMC - CB Certificate online

Ident. Nr.: 
98323 
Date:  
2008-3-11 
 
98323__EMC_TRF 
page 35 of 46 
11 Surge 
Immunity 
11.1 Standard 
Basic standard 
EN 61000-4-5:2006 
Date of testing 
2008.2.25 
Performance criteria: 
11.2 Measurement equipment 
 
Equipment 
Last Calibration
Type 
 
Serial No
.  
Manufacturer 
  Immunity Simulator 
February 25, 
2008 
EMC PRO 
SB2617 
KEYTEK 
11.3 Test set-up 
See annex B  
The EUT and the auxiliary equipment were placed on a table of 0.8m heights above a metal ground 
reference plane. The size of ground plane is greater than 1m×1m and project beyond the EUT by at 
least 0.1m on all sides. The ground plane is connected to the protective earth. The length of power 
cord between the coupling device and the EUT was less than 2 meters (provided by the 
manufacturer).  
The surge noise shall be applied synchronized to the voltage phase at 0
o
,90
o
,180
o
,270
o
 and the peak 
value of the a.c. voltage wave. (Positive and negative). 
Each of Line-Line is impressed with a sequence of five surge voltages with interval of 1 min. 
11.4 Test results 
Mode 
Table 
Remarks 
Result 
TM1; 
TM2 
015 
Tr/Th 1,2/50(8/20) μs 
Line to line 1kV  
Test to input a.c. power port 
(Signal port can not  directly 
connect to outdoor cable)
 
Pass   
 
11.5 Table 
11.5.1 Table 015 
 
Injected 
Line 
Wave 
Form 
Voltage
(kV) 
Phase 
Number of 
Pulse 
Interval 
time 
Result
+1 
0
o
,90
o
, 180
o
,270
20 60s 
Pass 
L-N 
1.2/50μs 
-1 
0
o
,90
o
, 180
o
,270
20 60s 
Pass 
Page of 46
Display