ON STAGE 200ID (serv.man3) - JBL Audio EMC - CB Certificate (repair manual). Page 30

Read JBL ON STAGE 200ID (serv.man3) EMC - CB Certificate online

Ident. Nr.: 
98323 
Date:  
2008-3-11 
 
98323__EMC_TRF 
page 30 of 46 
Electrostatic discharge, ESD 
8.1 Standard 
Basic standard 
EN 61000-4-2:1995/A11998/A22001 
Date of testing 
2008.2.27 
Performance criteria: 
8.2 Measurement equipment 
 
Equipment 
Last Calibration 
Type 
 
Serial No
.  
Manufacturer 
  ESD tester  
September 26, 2007 
ESD 30C 
SB4076 
EMTEST  
8.3 Test set-up 
See annex B 
The EUT shall be exposed to at least 200 discharges , 100 each at negative and positive polarity ,at a 
min of four test points (a min of 50 discharges at each point),One of the test points shall be subjected 
to at least 50 indirect discharges(contact) to the centre of the front edge of the hori coupling plane,The 
remaining three points shall each receive at least 50 direct contact discharges. If no direct contact test 
points are available,then at least 200 indirect discharges shall be applied in the indirect mode.Test shall 
be performed at a max repetition of one discharge per second. 
On those parts of the EUT where it is not possible to perform contact discharge testing ,the equipment 
should be investigated to identify user accessible points where breakdown may occur; A min of 10 
single air discharges shall be applied to the selected test point for each such area. 
 
Direct application of discharges to the EUT: 
Contact discharge was applied only to conductive surfaces of the EUT. 
Air discharges were applied only to non-conductive surfaces of the EUT. 
During the test, it was performed with single discharges. For the single discharge time between 
successive single discharges will be keep longer 1 second. It was at least ten single discharges with 
positive and negative at the same selected point. 
 
Indirect application of discharges to the EUT: 
Vertical Coupling Plane (VCP): 
The coupling plane, of dimensions 0.5m x 0.5m, is placed parallel to, and positioned at a distance 0.1m 
from, the EUT, with the Discharge Electrode touching the coupling plane. 
The four faces of the EUT will be performed with electrostatic discharge. It was at least ten single 
discharges with positive and negative at the same selected point. 
Horizontal Coupling Plane (HCP): 
The coupling plane is placed under to the EUT. The generator shall be positioned vertically at a 
distance of 0.1m from the EUT, with the Discharge Electrode touching the coupling plane. 
The four faces of the EUT will be performed with electrostatic discharge. It was at least ten single 
discharges with positive and negative at the same selected point. 
 
 
 
 
 
 
 
 
 
Page of 46