ON STAGE 200ID (serv.man3) - JBL Audio EMC - CB Certificate (repair manual). Page 34

Read JBL ON STAGE 200ID (serv.man3) EMC - CB Certificate online

Ident. Nr.: 
98323 
Date:  
2008-3-11 
 
98323__EMC_TRF 
page 34 of 46 
 
10 Electrical 
Fast 
Transients/Bursts Immunity 
10.1 Standard 
Basic standard 
EN 61000-4-4:2004 
Date of testing 
2008.2.25 
Performance criteria: 
10.2 Measurement equipment 
 
Equipment 
Last Calibration
Type 
 
Serial No
.  
Manufacturer 
  EFT simulator 
February 25, 
2008 
NSG2025-1 SB2556  SCHNAFFNER 
10.3 Test set-up 
See annex B  
The EUT is placed on a table that is 0.8meter height. A ground reference plane is placed on the table, 
and uses a 0.1m insulation between the EUT and ground reference plane. 
The minimum area of the ground reference plane is 1m*1m, and projected beyond the EUT by at least 
0.1m on all sides. 
Test on power supply ports: 
The duration time of each test sequential was 1 minute. 
The length of the signal and power lines between the coupling device and the EUT is 0.5m. 
10.4 Test results 
Mode 
Table 
Remarks 
Result 
TM1; 
TM2 
014 
±
1KV  
Tr/Th: 5/50ns 
Repetition frequency:5kHz 
Test to input a.c. power port 
(Signal port cable is less than 3m) 
Pass   
10.5 Table 
10.5.1 Table 014 
 
Injected Line 
Voltage 
(kV) 
Duration time 
(s) 
Injected Method 
Result 
+1 60 
Direct 
Pass 
-1 60 
Direct 
Pass 
+1 60 
Direct 
Pass 
-1 60 
Direct 
Pass 
+1 60 
Direct 
Pass 
L,N 
-1 60 
Direct 
Pass 
Page of 46