Read JBL ON STAGE 200ID (serv.man3) EMC - CB Certificate online
Ident. Nr.:
98323
Date:
2008-3-11
98323__EMC_TRF
page 31 of 46
8.4 Test results
Mode
Table
Remarks
Result
TM1;
TM2
012 Air
discharge:±8KV
Contact discharge:±4KV
Pass
8.5 Tables
8.5.1 Table 012
Location
Discharge
Method
Test Voltage
Amount of
test points
test points
Amount of
discharge
discharge
Result
HCP
[Horizontal Coupling Plane]
Indirect Contact
±4kV
4 200
Pass
VCP
[Vertical Coupling Plane]
Indirect Contact
±4kV
4 200
Pass
Nonconductive Enclosure
Air
±8kV
10 500
Pass
Conductive Enclosure
Direct Contact
±4kV
6 300
Pass