Read JBL ON STAGE 200ID (serv.man3) EMC - CB Certificate online
Ident. Nr.:
98323
Date:
2008-3-11
98323__EMC_TRF
page 36 of 46
12 Conducted
Immunity
12.1 Standard
Basic standard
EN 61000-4-6:1996/A1:2001
Date of testing
2008.2.25
Performance criteria:
A
12.2 Measurement equipment
Equipment
Last Calibration
Type
Serial No
.
Manufacturer
CW sine Generator
January 25,
2008
2008
CWS500 SB2605
EMTEST
CDN January
25,
2008
CDN-M2 SB2605/01
EMTEST
12.3 Test set-up
See annex B
The EUT are placed on a table that is 0.8 meter height, and a Ground reference plane on the table,
EUT are placed upon table and use a 10cm insulation between the EUT and Ground reference plane.
For Input DC and AC Power Ports: The EUT is connected to the power mains through a coupling and
decoupling networks for power supply lines. And directly couples the disturbances signal into EUT.
The EUT are placed on a table that is 0.8 meter height, and a Ground reference plane on the table,
EUT are placed upon table and use a 10cm insulation between the EUT and Ground reference plane.
For Input DC and AC Power Ports: The EUT is connected to the power mains through a coupling and
decoupling networks for power supply lines. And directly couples the disturbances signal into EUT.
12.4 Test results
Mode
Table
Remarks
Result
TM1;
TM2
016
1. Field Strength :3V(unmodulated,r.m.s)
2. Test Signal: AM 80% Modulated with 1kHz
3. Scanning Frequency :0.15MHz – 80MHz
4. Source impedance 150Ω
2. Test Signal: AM 80% Modulated with 1kHz
3. Scanning Frequency :0.15MHz – 80MHz
4. Source impedance 150Ω
Pass
12.5 Table
12.5.1 Table 016
Frequency Range
(MHz)
Injecteded Position
Strength
Result
0.15MHz ~ 80MHz
AC Lines
3V(r.m.s, Unmodulated)
Pass
Dwell time:0.5s; Steps: 1%
Click on the first or last page to see other ON STAGE 200ID (serv.man3) service manuals if exist.