ON STAGE 200ID (serv.man3) - JBL Audio EMC - CB Certificate (repair manual). Page 36

Read JBL ON STAGE 200ID (serv.man3) EMC - CB Certificate online

Ident. Nr.: 
98323 
Date:  
2008-3-11 
 
98323__EMC_TRF 
page 36 of 46 
 
12 Conducted 
Immunity 
12.1 Standard 
Basic standard 
EN 61000-4-6:1996/A1:2001 
Date of testing 
2008.2.25 
Performance criteria: 
12.2 Measurement equipment 
 
Equipment 
Last Calibration
Type 
 
Serial No
.  
Manufacturer 
  CW sine Generator  
January 25, 
2008 
CWS500 SB2605
 
EMTEST 
  CDN January 
25, 
2008 
CDN-M2 SB2605/01
 
EMTEST 
 
12.3 Test set-up 
See annex B  
The EUT are placed on a table that is 0.8 meter height, and a Ground reference plane on the table, 
EUT are placed upon table and use a 10cm insulation between the EUT and Ground reference plane. 
For Input DC and AC Power Ports: The EUT is connected to the power mains through a coupling and 
decoupling networks for power supply lines. And directly couples the disturbances signal into EUT. 
 
12.4 Test results 
Mode 
Table 
Remarks 
Result 
TM1; 
TM2 
016 
1. Field Strength :3V(unmodulated,r.m.s) 
2. Test Signal: AM 80% Modulated with 1kHz 
3. Scanning Frequency :0.15MHz – 80MHz 
4. Source impedance 150Ω 
Pass   
 
12.5 Table 
12.5.1 Table 016 
 
Frequency Range 
(MHz) 
Injecteded Position
Strength 
Result 
0.15MHz ~ 80MHz 
AC Lines 
3V(r.m.s, Unmodulated)
Pass 
Dwell time:0.5s; Steps: 1% 
 
 
 
 
 
 
 
 
 
Page of 46