ON BEAT XTREME (serv.man8) - JBL Audio EMC - CB Certificate (repair manual). Page 115

Read JBL ON BEAT XTREME (serv.man8) EMC - CB Certificate online

 
Page 2 of 12
 
Report No.: 171153
 
 
 
 
 
 
 
ATTACHMENT 7 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
3.2 Addition: 
Add the following after the first sentence of this  
sub-clause. 
NOTE Equipment often transported and used 
should not be Class I equipment nor Class 0I 
equipment. 
Class II
 
N/A
 
4.2.8 
Deletion: 
Delete this clause. 
 
— 
4.3.4, b) 
Replacement: 
Replace IEC 60730-1 by JIS C 9730-1 
(corresponding to IEC 60730-1). 
No PTC’s thermistors.
 
N/A
 
4.3.12 
Deletion: 
Delete this clause. 
 
— 
4.3.13 Replacement: 
Replace “250 V a.c.” by “the maximum of the 
variable range”. 
No voltage setting devices 
N/A 
5.4.2A Addition: 
For CLASS 0I EQUIPMENT, the following 
instruction shall be indicated where readily visible 
on the mains plug or the product: 
“WARNING:  Provide an earthing connection”  
Example in Japanese: 
 
 
Moreover, for CLASS 0I EQUIPMENT, the 
following instruction shall be indicated where 
readily visible on the product or written in the 
operating instructions: 
“WARNING:  Provide an earthing connection 
before the mains plug is connected to the mains. 
And, when disconnecting the earthing connection, 
be sure to disconnect after pulling out the mains 
plug from the mains.” 
Example in Japanese: 
 
Class II apparatus 
N/A 
Page of 126
Display