Read JBL ON BEAT XTREME (serv.man8) EMC - CB Certificate online
Page 2 of 12
Report No.: 171153
ATTACHMENT 7
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
3.2 Addition:
Add the following after the first sentence of this
sub-clause.
sub-clause.
NOTE Equipment often transported and used
should not be Class I equipment nor Class 0I
equipment.
should not be Class I equipment nor Class 0I
equipment.
Class II
N/A
4.2.8
Deletion:
Delete this clause.
Delete this clause.
—
4.3.4, b)
Replacement:
Replace IEC 60730-1 by JIS C 9730-1
(corresponding to IEC 60730-1).
Replace IEC 60730-1 by JIS C 9730-1
(corresponding to IEC 60730-1).
No PTC’s thermistors.
N/A
4.3.12
Deletion:
Delete this clause.
Delete this clause.
—
4.3.13 Replacement:
Replace “250 V a.c.” by “the maximum of the
variable range”.
variable range”.
No voltage setting devices
N/A
5.4.2A Addition:
For CLASS 0I EQUIPMENT, the following
instruction shall be indicated where readily visible
on the mains plug or the product:
instruction shall be indicated where readily visible
on the mains plug or the product:
“WARNING: Provide an earthing connection”
Example in Japanese:
Moreover, for CLASS 0I EQUIPMENT, the
following instruction shall be indicated where
readily visible on the product or written in the
operating instructions:
following instruction shall be indicated where
readily visible on the product or written in the
operating instructions:
“WARNING: Provide an earthing connection
before the mains plug is connected to the mains.
And, when disconnecting the earthing connection,
be sure to disconnect after pulling out the mains
plug from the mains.”
before the mains plug is connected to the mains.
And, when disconnecting the earthing connection,
be sure to disconnect after pulling out the mains
plug from the mains.”
Example in Japanese:
Class II apparatus