ATTACHMENT 6
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
15.2
Provisions for protective earthing - Bond
Impedance
Replace the third paragraph with the following:
Earthing connections shall comply with the test
requirements of CSA C22.2 No 0.4.
Impedance
Replace the third paragraph with the following:
Earthing connections shall comply with the test
requirements of CSA C22.2 No 0.4.
Class ll apparatus
N/A
15.3
15.3.1A
Terminals for external flexible cords and
permanent connections to the mains supply
permanent connections to the mains supply
(Permanent Wiring)
Add the following clauses:
Equipment intended for permanent connection to
the mains shall have provisions for connection to
the wiring system in accordance with the Canadian
Electrical Code, Part I.
Add the following clauses:
Equipment intended for permanent connection to
the mains shall have provisions for connection to
the wiring system in accordance with the Canadian
Electrical Code, Part I.
Appliance inlet applied
N/A
The terminal parts and all other provisions for
permanent connection to fixed wiring shall comply
with CSA Standard CAN/CSA-C22.2 No 0.
permanent connection to fixed wiring shall comply
with CSA Standard CAN/CSA-C22.2 No 0.
Apparatus is not for
permanent connection.
permanent connection.
N/A
15.4.2
(Mains Plugs – Type)
Add the following paragraphs:
Mains plugs of non-permanently installed
equipment shall comply with:
Add the following paragraphs:
Mains plugs of non-permanently installed
equipment shall comply with:
a)
CSA C22.2 No 21 for moulded-on type
attachment plugs; and
b)
CSA C22.2 No 42 for disassembly type
attachment plugs (dimensional requirements are
also specified in IEC 60906-2).
also specified in IEC 60906-2).
CSA approved attachment plug
P
Class II equipment provided with a general
purpose mains outlet, or lampholder, shall be
provided with a polarized-type plug.
purpose mains outlet, or lampholder, shall be
provided with a polarized-type plug.
N/A
If the plug is a polarized type, single pole switches
or over current protectors shall not be
connected in the identified conductor.
or over current protectors shall not be
connected in the identified conductor.
P