Read JBL ON BEAT XTREME (serv.man8) EMC - CB Certificate online
Page 11 of 11
Report No.: 171153
ATTACHMENT 6
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
18
18.1A
Mechanical strength of picture tubes and
protection against the effects of implosion
(Cathode Ray Tubes)
Add the following clause:
A picture tube with a maximum face dimensions
exceeding 75mm either shall be intrinsically
protected with respect to effects of implosion and
to mechanical impact, in accordance with
CAN/CSA C22.2 No 228 or CAN/CSA E61965, or
the enclosure of the apparatus shall provide
adequate protection against the effects of an
implosion of the tube (see Clause 12).
protection against the effects of implosion
(Cathode Ray Tubes)
Add the following clause:
A picture tube with a maximum face dimensions
exceeding 75mm either shall be intrinsically
protected with respect to effects of implosion and
to mechanical impact, in accordance with
CAN/CSA C22.2 No 228 or CAN/CSA E61965, or
the enclosure of the apparatus shall provide
adequate protection against the effects of an
implosion of the tube (see Clause 12).
N/A
19
Stability and Mechanical Hazards
Add the following after the second paragraph:
The test of 19.3 is only required for:
Add the following after the second paragraph:
The test of 19.3 is only required for:
a) Apparatus with a mass of 25 kg or more; or
b) Apparatus,
excluding
loudspeaker systems,
with a height of 1m or more; or
c) Apparatus, including loudspeaker systems, in
combination with a supplied or recommended
cart of stand with a total height of 1m or more.
cart of stand with a total height of 1m or more.
Mass of 4.1 Kg
N/A
Add the following paragraph:
Apparatus not tested because it is intended to be
fastened in place shall be provided with the
following warning, marked on the apparatus or on
a durable label attached to the mains cord:
“WARNING: This apparatus must be securely
attached to the floor /wall per installation
instructions. Tipping, shaking, or rocking the
machine may cause injury / death”
Apparatus not tested because it is intended to be
fastened in place shall be provided with the
following warning, marked on the apparatus or on
a durable label attached to the mains cord:
“WARNING: This apparatus must be securely
attached to the floor /wall per installation
instructions. Tipping, shaking, or rocking the
machine may cause injury / death”
N/A
20
20.2.1A
Fire enclosure
(Projector Lamp Enclosure)
Add the following clause:
Enclosures of apparatus containing high voltage or
projection lamps shall have a minimum
flammability rating of category FV1 according to
IEC 60707 at the minimum thickness used.
(Projector Lamp Enclosure)
Add the following clause:
Enclosures of apparatus containing high voltage or
projection lamps shall have a minimum
flammability rating of category FV1 according to
IEC 60707 at the minimum thickness used.
N/A
Annex B
Apparatus to be connected to the
telecommunications networks
Replace this annex with the following:
Apparatus intended for direct connection to a
TELECOMMUNICATION NETWORK shall comply
with:
a) Clause 19 of CSA C22.2 No 1; or
b) CAN/CSA C22.2 No. 60950.
telecommunications networks
Replace this annex with the following:
Apparatus intended for direct connection to a
TELECOMMUNICATION NETWORK shall comply
with:
a) Clause 19 of CSA C22.2 No 1; or
b) CAN/CSA C22.2 No. 60950.
N/A