Read JBL JEMBE WIRELESS (serv.man2) EMC - CB Certificate online
Report No. SF201200115 Page 14 of 32
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
14.8
Voltage setting devices and the like
No such component
N
Voltage setting device not likely to be changed
accidentally
accidentally
N
14.9
Motors
N
14.9.1
Endurance test on motors
N
Motor start test
N
Dielectric strength test
N
14.9.2
Not adversely affected by oil or grease etc.
N
14.9.3
Protection against moving parts
N
14.9.4
Motors
with
phase-shifting
capacitors,
three-phase motors and series motors meet
clause. B.8, B.9 and B.10 of IEC 60950,
Annex B
clause. B.8, B.9 and B.10 of IEC 60950,
Annex B
Not such motors.
N
14.10
Batteries
Battery in remote control.
P
14.10.1
Batteries mounted with no risk of accumulation
of flammable gases
of flammable gases
P
14.10.2
No possibility of recharging non-rechargeable
batteries
batteries
P
14.10.3
Recharging
currents
and
times
within
manufacturers limits
Lithium battery.
N
Lithium batteries discharge and reverse currents
within the manufacturers limits
within the manufacturers limits
P
14.10.4
Battery mould stress relief
N
14.10.5
Battery drop test
P
14.11
Optocouplers
No optocouplers
N
Optocouplers comply with Cl. 8
N
N
14.12
Surge suppression varistors
No such component
N
Comply with IEC 61051-2
N
Not connected between mains and accessible
parts except for earthed parts of permanently
connected apparatus
parts except for earthed parts of permanently
connected apparatus
N
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12
thermal stress requirements of 14.12
N
Click on the first or last page to see other JEMBE WIRELESS (serv.man2) service manuals if exist.