JEMBE WIRELESS (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 12

Read JBL JEMBE WIRELESS (serv.man2) EMC - CB Certificate online

Report No. SF201200115                                                                                                        Page 12 of 32 
EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
14.3.4.1 
Class II  transformers  have  adequate  separation 
between  hazardous  live  parts  and  accessible 
parts (double or reinforced insulation) 
 
 
Coil formers and partition walls > 0,4 mm 
 
14.3.4.2 
Class I  transformers,  with  basic  insulation  and 
protective  screening  only  if  all  7  conditions  of 
14.3.4.2 are met 
 
14.3.4.3 
Separating  transformers  with  at  least  basic 
insulation 
 
14.3.5.1 
Class II  transformers  have  adequate  insulation 
between  hazardous  live  parts  and  accessible 
parts (double or reinforced insulation) 
 
 
Coil formers and partition walls > 0,4 mm 
 
14.3.5.2 
Class I  transformers  have  adequate  insulation 
between  hazardous  live  parts  and  accessible 
conductive  parts  or  those  conductive  parts  or 
protective  screens  connected  to  a  protective 
earth terminal 
 
 
Winding  wires  connected  to  protective  earth 
have adequate current-carrying capacity 
 
14.4 
High voltage components 
No high voltage components 
 
High-voltage  components  and  assemblies: 
U > 4 kV (peak) separately approved 
(see appended table) 
 
Component meets category V-1 of IEC 60707 
 
14.4.1 
High voltage transformers and multipliers tested 
as part of the submission 
 
14.4.2 
High  voltage  assemblies  and  other  parts  tested 
as part of the submission 
 
14.5 
Protective devices 
 
 
Protective devices used within their ratings 
 
 
External  clearances  and  creepage  distances 
meet  requirement  of  clause  13  for  the  voltage 
across the device when opened 
No insulation requirement. 
14.5.1.1 
a) Thermal cut-outs separately approved 
No such component 
 
b)  Thermal  cut-outs  tested  as  part  of  the 
submission 
 
14.5.1.2 
a) Thermal links separately approved 
 
 
b) Thermal links tested as part of the submission   
14.5.1.3 
Thermal devices re-settable by soldering 
 
14.5.2.1 
Fuse-links  in  the mains  circuit  according  to  IEC 
60127 
Not connect to the mains. 
see appended table 14 