Read JBL JEMBE WIRELESS (serv.man2) EMC - CB Certificate online
TEST REPORT
Report No.:
SF201200115
Page 1 of 32
Client:
Harman International Industries, Incorporated
Address:
Sample Description: Speaker System
Model:
JEMBE WIRELESS
Test Location:
GUANGZHOU GRG METROLOGY&TEST CO.,LTD.
GRGT
’S SAFETY LAB
Test Specification:
EN 60065 : 2002 + A1:2006 + A2:2010 + A11:2008 + A12:2011
Audio, video and similar electronic apparatus - Safety requirements
Test Date:
2012-04-10 --- 2012-04-15
Test Result:
According to the kind and extend of tests performed the test item passed
test specification.
Tested By:
Reviewed By:
Approved By:
JJ Teng / Test Engineer
Jamie Zhou / Engineer
Connie Yang / Manager
Date: 2012.04.26
Date: 2012.04.26
Date: 2012.04.26
Other Aspects:
N.A.
Abbreviations: ok / P = passed; fail / F = failed; n.a. / N = not applicable
The test result in this test report refers exclusively to the presented test sample. This report shall not be reproduced except in
full, without the written approval of GRGT.
GUANGZHOU GRG METROLOGY&TEST CO.,LTD.
Address: 163, Pingyun Road, West of Huangpu Avenue, Guangzhou, Guangdong, P.R. China
Tel:+86-20-38699960
Fax:+86-20-38695185
Email: [email protected]
Ver.:1.0 / 09.Sep.2008
Report No.
SF201200115
Page 2 of 32
Test Report
EN 60065
Audio, Video and similar electronic apparatus - Safety requirements
Testing laboratory
………….……….. : GUANGZHOU GRG METROLOGY&TEST CO., LTD.
Address
………………………... …….: 163 Pingyun Road West of Huangpu Avenue Tianhe District
Guangzhou City, 510656, P. R. China
Standard
……………………………….: EN 60065 : 2002 + A1:2006 + A2:2010 + A11:2008 + A12:2011
Test Result
……………………............: Pass
Procedure deviation
…………………..: N.A
Non-standard test method
……..........: N.A
Basic model
……………………………: JEMBE WIRELESS
Rating
…………………………….........: 12V
, 1.5A
Trademark
……………………….........: JBL
Listed Model
…………………………..: ---
Manufacturer
…………………………: Guo Guang Electric Co., Ltd.
Address
…………………………….….: No.8 Jinghu Road, Xinhua Street, Huadu Reg, Guangzhou,
510800 P.R.China
Factory
…………………………………: ---
Address
…………………………….….: ---
General remarks
This report shall not be reproduced except in full without the written approval of the testing laboratory.
The test results presented in this report relate only to the item(s) tested.
“(see appended table)” refers to a table appended to the report.
“(see Annex A)” refers to an annex appended to the report.
Report No.
SF201200115
Page 3 of 32
General product information:
1. The equipment not directly connect to the MAINS.
2. The equipment is supplied by a power adapter which was separately approved.
Conditions of Acceptability:
1. Installation instruction and equipment markings related to safety shall be provided in a language
acceptable to the country where the equipment is intended to be used.
acceptable to the country where the equipment is intended to be used.
Copy of marking plate:
Report No. SF201200115 Page 4 of 32
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
3
GENERAL REQUIREMENTS
P
Safety class of the apparatus ............................. : Supplied by 12V DC, no
hazardous voltage generate
circuit. in the apparatus.
circuit. in the apparatus.
N
4
GENERAL CONDITIONS OF TESTS
P
4.1.4
Ventilation instructions require the use of the test
box
box
Provide with user manual.
P
5
MARKING
P
Comprehensible and easily discernible
Considered.
P
Permanent
durability
against
water
and
petroleum spirit
YES
P
5.1
Identification, maker, model ............................... : See marking plate.
P
Class II symbol if applicable
Not connect to mains.
N
Rated supply voltage and symbol ...................... : DC 12V with the symbol of
IEC 60417-5031
P
Frequency if safety dependant
N
Rated current or power consumption ................ : 1.5A
P
5.2
Earth terminal
No such terminal.
N
Hazardous live terminals
No such terminal.
N
Supply output terminals (other than mains)
No such terminal.
N
5.3
Use of triangle with exclamation mark
N
5.4
Instructions for use
User manual.
P
5.4.1
Mains powered equipment not exposed to
dripping or splashing. Warning concerning
objects filled with liquid, etc.
dripping or splashing. Warning concerning
objects filled with liquid, etc.
Not connect to Mains.
With similar text in manual.
N
Hazardous live terminals, instructions for wiring
N
Instructions for replacing lithium battery
P
Instructions for modem if fitted
N
Class I earth connection warning
Not Class I equipment
N
Instructions for multimedia system connection
P
Special stability warning for fixed installation
N
Warning: battery exposure to heat
With similar text in manual.
P
Warning: protective film on CRT face
No CRT
N
5.4.2
Disconnect device: plug/coupler or all-pole
mains switch location, accessibility and markings
mains switch location, accessibility and markings
Not connect to Mains
N