Report No. SF201200115 Page 16 of 32
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
15.3.4
Soldered conductors wrapped around terminal
prior to soldering or held in place by additional
means
prior to soldering or held in place by additional
means
N
Clamping of conductor and insulation if not
soldered or held by screws
soldered or held by screws
N
15.3.5
Terminals allow connection of appropriate
cross-sectional area of conductors, for the rated
current of the equipment
cross-sectional area of conductors, for the rated
current of the equipment
N
15.3.6
Terminals to 15.3.3 have sizes required by
table 16
table 16
N
15.3.7
Terminals clamp conductors between metal and
have adequate pressure
have adequate pressure
N
Terminals designed to avoid conductor slipping
out when tightened or loosened
out when tightened or loosened
N
Terminals adequately fixed to avoid loosening
when the clamping is tightened or loosened and
stress on internal wiring is avoided
when the clamping is tightened or loosened and
stress on internal wiring is avoided
N
15.3.8
Terminals carrying a current more than 0,2 A:
contact pressure not transmitted by insulating
material except ceramic
contact pressure not transmitted by insulating
material except ceramic
N
15.3.9
Termination of non-detachable cords: wires
terminated near to each other
terminated near to each other
N
Terminals located and shielded: test with 8 mm
strand
strand
N
15.4
Devices forming a part of the mains plug
Not such device.
N
15.4.1
No undue strain on mains socket-outlets
N
15.4.2
Device complies with standard for dimensions of
mains plugs
mains plugs
N
15.4.3
Device has adequate mechanical strength (tests
a,b,c)
a,b,c)
N
16
EXTERNAL FLEXIBLE CORDS
N
16.1
Mains cords sheathed type, complying with
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ........................................................ :
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ........................................................ :
Not connect to mains
N
Non-detachable
cords
for
Class I
have
green/yellow core for protective earth
N
16.2
Mains
cords
conductors
have
adequate
cross-sectional
area
for
rated
current
consumption of the equipment
N