Report No. SF201200115                                                                                                        Page 11 of 32 
EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
 
 
 
14 
COMPONENTS 
14.1 
Resistors 
 
a)  Resistors  between  hazardous  live  parts  and 
accessible metal parts 
(see appended table) 
 
b) Resistors, other than between hazardous live 
parts and accessible parts 
 
 
Resistors separately approved  .......................... :  Yes / No 
14.2 
Capacitors and RC units 
 
 
Capacitors separately approved 
Yes / No 
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 edition 
.............................................................................. : 
Y1 
Y2 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 edition 
.............................................................................. : 
X1 
X2 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2  ................. : 
 
14.2.5 
Capacitors  with  volume  exceeding  1750 mm
³, 
where  short-circuit  current  exceeds  0,2 A: 
compliance with IEC60384-1, 4.38 category B or 
better  ................................................................... : 
Metal-cased capacitors 
 
Capacitors  with  volume  exceeding  1750 mm
³, 
mounted  closer  to  a  potential  ignition  source 
than 
table 5 
permits: 
compliance 
with 
IEC 60 384-1, 4.38 category B or better ............ : 
 
 
Shielded by a barrier 
acc. to 20.1.4/ table 21
 or 
metal .................................................................... : 
Yes / No 
14.3 
Inductors and windings 
No such component 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4 
 
14.3.1 
Transformers  and  inductors  marked  with 
manufacturer's name and type ........................... : 
 
 
Transformers 
and 
inductors 
separately 
approved  ............................................................. : 
Yes / No 
14.3.2 
General 
 
 
Insulation material complies    with clause 20.1.4   
14.3.3 
Constructional requirements 
 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13 
 
14.3.3.2 
Transformers 
meet 
the 
constructional 
requirements 
 
Page of 32