Read JBL JEMBE WIRELESS (serv.man2) EMC - CB Certificate online
Report No. SF201200115 Page 9 of 32
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
Flames extinguish within 10 seconds
No flames.
P
Soldered terminations not used as protective
mechanism
mechanism
P
11.2.1
Measurement of temperature rises
(see appended table 11.2)
P
11.2.2
Temperature rise of accessible parts
(see appended table 11.2)
P
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
providing electrical insulation
N
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for
max. 5 min
exceeding the limits of table 3 by max. 100 K for
max. 5 min
N
a) Temperature rise of printed circuit boards
(PCB) to 20.1.3, exceeding the limits of table 3
by not more than 100 K for an area not greater
than 2 cm
(PCB) to 20.1.3, exceeding the limits of table 3
by not more than 100 K for an area not greater
than 2 cm
²
N
b) Temperature rise of printed circuit boards
(PCB) to 20.1.3 up to 300 K for an area not
greater than 2 cm
(PCB) to 20.1.3 up to 300 K for an area not
greater than 2 cm
² for a maximum of 5 min
N
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
N
Class I protective earthing maintained
N
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
N
11.2.5
Temperature rise of windings
N
11.2.6
Temperature rise of parts not subject to the limits
of 11.2.1 to 11.2.5
of 11.2.1 to 11.2.5
(see appended table 11.2)
P
12
MECHANICAL STRENGTH
N
12.1.1
Bump test where mass >7 kg
N
12.1.2
Vibration test
No hazardous live parts.
N
12.1.3
Impact hammer test
N
Steel ball test
N
12.1.4
Drop test for portable apparatus where mass < 7
kg
kg
Not such apparatus.
N
12.1.5
Thermoplastic enclosures strain relief test
No hazardous live parts.
N
12.2
Fixing of knobs, push buttons, keys and levers
No hazardous live parts.
N
12.3
Remote controls with hazardous live parts
No such component
N
12.4
Drawers (pull test 50 N, 10 s)
No such component
N
12.5
Antenna coaxial sockets providing isolation
N
12.6
Telescoping or rod antennas construction
No such component
N
Click on the first or last page to see other JEMBE WIRELESS (serv.man2) service manuals if exist.