Report No. SF201200115 Page 8 of 32
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
9.1.3
Ventilation holes and other holes tested by
means of 4 mm x 100 mm test pin
means of 4 mm x 100 mm test pin
No hazardous live parts.
N
9.1.4
Terminal devices tested with 1 mm x 20 mm test
pin (10 N); test probe D of IEC 61032
pin (10 N); test probe D of IEC 61032
No hazardous live parts.
N
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
No hazardous live parts.
N
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm
test pin (10 N); test probe C of IEC 61032
test pin (10 N); test probe C of IEC 61032
No such component
N
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after
2 s ........................................................................ :
withdrawal of the mains plug; voltage (V) after
2 s ........................................................................ :
Not connect to mains.
N
If C is not greater than 0,1
μF no test needed
N
9.1.7
a) Enclosure sufficiently resistant to external
force
force
No hazardous live parts.
N
Test probe 11 of IEC 61032 for 10 s (50 N)
N
b) Test hook of fig. 4 for 10 s (20 N)
N
c) 30 mm diameter test tool for 5 s (100 or
250 N) .................................................................. :
250 N) .................................................................. :
N
9.2
No hazard after removing a cover by hand
Removing of battery cover.
P
10
INSULATION REQUIREMENTS
N
10.1
Insulation resistance (M
Ω) at least 2 MΩ min.
after surge test for basic and 4 M
Ω min. for
reinforced insulation ........................................... :
Not connect to mains.
N
10.2
Humidity treatment 48 h or 120 h ....................... : 48 h
120 h
N
10.3
Insulation resistance and dielectric strength
between mains teminals
between mains teminals
N
Insulation Resistance and dielectric strength
across BASIC or SUPPLEMENTARY insulation
(Class 1)
across BASIC or SUPPLEMENTARY insulation
(Class 1)
N
Insulation resistance and dielectric strength
across REINFORCED insulation (Class II)
across REINFORCED insulation (Class II)
N
11
FAULT CONDITIONS
P
11.1
No shock hazard under fault condition
P
11.2
Heating under fault condition
P
No hazard from softening solder
No softening solder
P