Read Harman Kardon SB 30 (serv.man3) EMC - CB Certificate online
Page 11 of 52
Report No. : 12-1330-0135
IEC/EN 60065
Clause
Requirement
– Test
Result - Remark
Verdict
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
No pre-set controls used.
N/A
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after 2 s :
withdrawal of the mains plug; voltage (V) after 2 s :
0V after 2 s for all models.
Pass
If C is not greater than 0,1
μF no test needed
N/A
9.1.7
Enclosure sufficiently resistant to external force
No damage to the enclosure.
Pass
a)
Test probe 11 of IEC 61032 for 10 s (50 N)
Hazardous live part is not
accessible.
accessible.
Pass
b)
Test hook of fig. 4 for 10 s (20 N)
Hazardous live part is not
accessible.
accessible.
Pass
c)
Conductive enclosure: 30 mm diameter test tool for
5 s (100 or 250 N) ................................................... :
5 s (100 or 250 N) ................................................... :
250 N applied. Hazardous live
part is not accessible.
part is not accessible.
Pass
9.2
No hazard 2s after removing a cover by hand
No covers can be removed by
hand.
hand.
N/A
10
INSULATION REQUIREMENTS
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4
surge test for basic and 4
MΩ min. for reinforced
insulation ................................................................. :
The surge test, insulation
resistance test and dielectric
strength test have performed
resistance test and dielectric
strength test have performed
Pass
10.2
Humidity treatment 48 h or 120 h ........................... : At 93 % R.H., 120 hrs, 40 °C
Pass
10.3
Insulation resistance and dielectric strength
between mains terminals
between mains terminals
See below
Pass
Insulation resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class 1)
BASIC or SUPPLEMENTARY insulation (Class 1)
N/A
Insulation resistance across REINFORCED
insulation (Class II)
insulation (Class II)
(see appended table 10.3)
Pass
11
FAULT CONDITIONS
11.1
No shock hazard under fault condition
Accessible voltage remains non-
hazardous live.
See appended table 11.2.
hazardous live.
See appended table 11.2.
Pass
11.2
Heating under fault condition
See below
Pass
No hazard from softening solder
No solder point became soft.
Pass
No flaming more than 10s
N/A
Soldered terminations not used as protective
mechanism
mechanism
Pass
11.2.1
Measurement of temperature rises
Refer to appended table 11.2.
Pass
11.2.2
Temperature rise of accessible parts
Refer to appended table 11.2.
Pass
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
providing electrical insulation
Refer to appended table 11.2.
Pass