SB 30 (serv.man3) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 9

Read Harman Kardon SB 30 (serv.man3) EMC - CB Certificate online

 
Page 8 of 52 
Report No. : 12-1330-0135 
IEC/EN 60065 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
 
 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
(see appended table 7.1) 
Pass 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0,2 A at least 150
 o
No such component. 
N/A 
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION 
AGAINST ELECTRIC SHOCK 
 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare 
Considered. 
Pass 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc. 
Operations intended to be 
performed by hand do not 
result in an increased risk of 
shock hazard. 
N/A 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material 
 
N/A 
8.4 
No risk of electric shock following the removal of a 
cover which can be removed by hand 
No cover is removable by hand. 
Pass 
8.5 
Class I equipment 
 
 
 
Basic insulation between hazardous live parts and 
earthed accessible parts 
Class II apparatus. 
N/A 
 
Capacitors bridging basic insulation complying with 
14.2.1 a) 
 
N/A 
8.6 
Class II equipment and Class II constructions within Class I equipment 
 
Reinforced or double insulation between hazardous 
live parts and accessible parts 
 
Pass 
 
Components bridging reinforced or double 
insulation complying with 14.1 a) or 14.3 
Transformer complied with 14.3 
Pass 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.2.1 a) 
No such component used. 
N/A 
 
Reinforced or double insulation being bridged with 
2 capacitors in series complying with 14.2.1 a) 
No such component used. 
N/A 
 
Reinforced or double insulation being bridged with 
a single capacitor complying with 14.2.1 b) 
Bridged capacitor complied with 
14.2.1 
Pass 
 
Basic insulation bridged by components complying 
with 14.3.4.3 
No such component used. 
N/A 
8.7 
This sub-clause is void 
 
N/A 
 
 
 
 
8.8 
Double Insulation: the Basic or Supplementary 
insulation > 0,4 mm (mm)  ....................................... : 
 
N/A 
 
Reinforced insulation > 0,4 mm (mm)  .................... :  Heat shrinkable tubing coverd 
on power switch: min. 0.4 mm. 
The bobbin of transformer  
measured min. 0.71 mm 
Pass 
Page of 76
Display

Click on the first or last page to see other SB 30 (serv.man3) service manuals if exist.