Read Harman Kardon SB 30 (serv.man3) EMC - CB Certificate online
Page 8 of 52
Report No. : 12-1330-0135
IEC/EN 60065
Clause
Requirement
– Test
Result - Remark
Verdict
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table 7.1)
Pass
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
No such component.
N/A
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
Considered.
Pass
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
Operations intended to be
performed by hand do not
result in an increased risk of
shock hazard.
performed by hand do not
result in an increased risk of
shock hazard.
N/A
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
N/A
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
cover which can be removed by hand
No cover is removable by hand.
Pass
8.5
Class I equipment
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
Class II apparatus.
N/A
Capacitors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
N/A
8.6
Class II equipment and Class II constructions within Class I equipment
Reinforced or double insulation between hazardous
live parts and accessible parts
live parts and accessible parts
Pass
Components bridging reinforced or double
insulation complying with 14.1 a) or 14.3
insulation complying with 14.1 a) or 14.3
Transformer complied with 14.3
Pass
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
bridged by a capacitor complying with 14.2.1 a)
No such component used.
N/A
Reinforced or double insulation being bridged with
2 capacitors in series complying with 14.2.1 a)
2 capacitors in series complying with 14.2.1 a)
No such component used.
N/A
Reinforced or double insulation being bridged with
a single capacitor complying with 14.2.1 b)
a single capacitor complying with 14.2.1 b)
Bridged capacitor complied with
14.2.1
14.2.1
Pass
Basic insulation bridged by components complying
with 14.3.4.3
with 14.3.4.3
No such component used.
N/A
8.7
This sub-clause is void
N/A
8.8
Double Insulation: the Basic or Supplementary
insulation > 0,4 mm (mm) ....................................... :
insulation > 0,4 mm (mm) ....................................... :
N/A
Reinforced insulation > 0,4 mm (mm) .................... : Heat shrinkable tubing coverd
on power switch: min. 0.4 mm.
The bobbin of transformer
measured min. 0.71 mm
measured min. 0.71 mm
Pass
Click on the first or last page to see other SB 30 (serv.man3) service manuals if exist.