Read Harman Kardon SB 30 (serv.man3) EMC - CB Certificate online
Page 6 of 52
Report No. : 12-1330-0135
IEC/EN 60065
Clause
Requirement
– Test
Result - Remark
Verdict
3
GENERAL REQUIREMENTS
Safety class of the apparatus ................................. : Class II apparatus.
Pass
4
GENERAL CONDITIONS OF TESTS
4.1.4
Ventilation instructions require the use of the test
box
box
Temperature measurements were
carried out in the open-fronted
wooden box in the standard.
carried out in the open-fronted
wooden box in the standard.
Pass
5
MARKING
Comprehensible and easily discernible
Compliance is checked by
inspection and by rubbing the
marking by hand for 15s with a
piece of cloth soaked with water
and, at a different place or on a
second sample, for 15s with a
piece of cloth soaked with
petroleum spirit. After this the
marking shall be legible, it shall
not be easily possible to remove
marking plates and they shall
show to curling.
inspection and by rubbing the
marking by hand for 15s with a
piece of cloth soaked with water
and, at a different place or on a
second sample, for 15s with a
piece of cloth soaked with
petroleum spirit. After this the
marking shall be legible, it shall
not be easily possible to remove
marking plates and they shall
show to curling.
Pass
Permanent durability against water and petroleum
spirit
spirit
After rubbing test by water and
petroleum spirit, the label still
easily discernible, indelible and
legible.
petroleum spirit, the label still
easily discernible, indelible and
legible.
Pass
5.1
a), b)
Identification, maker, model ................................... :
Trademark:
Model: (1)SB 30 CNTR, (2)SB
30 SUB, (3)SB 30 SUB/230
30 SUB, (3)SB 30 SUB/230
Pass
c)
Class II symbol if applicable
Symbol 60417-5172 marked in
the label.
the label.
Pass
d), e)
Rated supply voltage and symbol ........................... : (1)100-120 V~, 220-240 V~
(2)100-120 V~
(3)220-240 V~
(3)220-240 V~
Pass
f)
Frequency if safety dependant
(1)50/60Hz, 50Hz
(2)50/60 Hz
(3)50/60 Hz
(2)50/60 Hz
(3)50/60 Hz
Pass
g), h), i)
Rated current or power consumption ..................... : (1) 4A, 2A
(2) 100W
(3) 100W
(3) 100W
Pass
5.2
a)
Earth terminal
Class II apparatus.
N/A
b)
Hazardous live terminals
No hazardous live parts.
N/A
c)
Supply output terminals (other than mains)
No socket outlet for providing
power to other apparatus.
power to other apparatus.
N/A
5.3
Use of triangle with exclamation mark
Symbol according to ISO
7000-0434 in circuit diagram.
7000-0434 in circuit diagram.
Pass