Read Harman Kardon SB 30 (serv.man3) EMC - CB Certificate online
Page 10 of 52
Report No. : 12-1330-0135
IEC/EN 60065
Clause
Requirement
– Test
Result - Remark
Verdict
8.19.1
Disconnect device
AC Inlet is used as the
disconnect device and see also
sub-clause 5.4.2
disconnect device and see also
sub-clause 5.4.2
Pass
All-pole switch or circuit breaker with >3mm contact
separation
separation
Complied.
Pass
8.19.2
Mains switch ON indication
Complied.
Pass
8.20
Switch not fitted in the mains cord
No such component used.
N/A
8.21
Bridging components comply with clause 14
Complied.
Pass
8.22
Test of non-separable thin sheet material
No such component used.
N/A
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
9.1
Testing on the outside
Pass
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
N/A
9.1.1.1 a) Determination of Hazardous Live parts
See below
Pass
b) Touch current measured from terminal devices
using the network in annex D ................................. :
The following parts were
measured the maximum open-
circuit voltage that exceeds 35
Vpeak or 60Vdc.
measured the maximum open-
circuit voltage that exceeds 35
Vpeak or 60Vdc.
Class II construction:
accessible connector and
metal part for SB 30 CNTR
U1: 0.49Vpeak
U2: 0.34Vpeak
accessible metal part for SB
30 SUB/230
U1: 0.328Vpeak
U2: 0.267Vpeak
Pass
c) Discharge not exceeding 45
μC
Complied.
Pass
d) Energy of discharge not exceeding 350 mJ
No voltage exceeds 15kVdc.
N/A
9.1.1.2
Test with test finger and test probe
Pass
9.1.2
No hazardous live shafts of knobs, handles or
levers
levers
Shafts of operating knobs,
handles, levers and the like are
not hazardous live.
handles, levers and the like are
not hazardous live.
Pass
9.1.3
Ventilation holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
Test pin is not become
hazardous live.
hazardous live.
Pass
9.1.4
Terminal devices - within 25mm tested with
1 mm x 20 mm test pin (10 N); test probe D of IEC
61032
1 mm x 20 mm test pin (10 N); test probe D of IEC
61032
Certified inlet used. All output
terminals did not become
hazardous live after test.
terminals did not become
hazardous live after test.
Pass
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
See above.
Pass
Click on the first or last page to see other SB 30 (serv.man3) service manuals if exist.