Report No. : 12-1330-0135 
IEC/EN 60065 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
 
 
8.19.1 
Disconnect device 
AC Inlet is used as the 
disconnect device and see also 
sub-clause 5.4.2 
Pass 
 
All-pole switch or circuit breaker with >3mm contact 
separation 
Complied. 
Pass 
8.19.2 
Mains switch ON indication 
Complied. 
Pass 
8.20 
Switch not fitted in the mains cord 
No such component used. 
N/A 
8.21 
Bridging components comply with clause 14 
Complied. 
Pass 
8.22 
Test of non-separable thin sheet material 
No such component used. 
N/A 
 
 
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS 
9.1 
Testing on the outside 
Pass 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
 
N/A 
9.1.1.1    a)  Determination of Hazardous Live parts 
See below 
Pass 
b)  Touch current measured from terminal devices 
using the network in annex D  ................................. : 
The following parts were 
measured the maximum open-
circuit voltage that exceeds 35 
Vpeak or 60Vdc. 
Class II construction: 
  accessible connector and 
metal part for SB 30 CNTR 
U1:  0.49Vpeak 
U2:  0.34Vpeak 
  accessible metal part for SB 
30 SUB/230 
U1:  0.328Vpeak 
U2:  0.267Vpeak 
Pass 
c)  Discharge not exceeding 45 
μC 
Complied. 
Pass 
d)  Energy of discharge not exceeding 350 mJ 
No voltage exceeds 15kVdc. 
N/A 
9.1.1.2 
Test with test finger and test probe 
 
Pass 
9.1.2 
No hazardous live shafts of knobs, handles or 
levers 
Shafts of operating knobs, 
handles, levers and the like are 
not hazardous live. 
Pass 
9.1.3 
Ventilation holes tested by means of 
4 mm x 100 mm test pin 
Test pin is not become 
hazardous live. 
Pass 
9.1.4 
Terminal devices - within 25mm tested with 
1 mm x 20 mm test pin (10 N); test probe D of IEC 
61032 
Certified inlet used. All output 
terminals did not become 
hazardous live after test.  
Pass 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032 
See above. 
Pass 