Report No. : 12-1330-0135
IEC/EN 60065
Clause
Requirement
– Test
Result - Remark
Verdict
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
See below.
Pass
Coil formers and partition walls = 0,4 mm
The bobbin of transformer
measured min. 0.71 mm
measured min. 0.71 mm
Pass
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
Class II transformer.
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
Same as above.
N/A
14.4
High voltage components
N/A
High-voltage components and assemblies:
U > 4 kV (peak) separately approved
U > 4 kV (peak) separately approved
No high voltage components.
N/A
Component meets category V-1 of IEC 60707
Same as above.
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
Same as above.
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
Same as above.
N/A
14.5
Protective devices
Pass
Protective devices used within their ratings
For model SB 30 CNTR:
T 4.0 AL, 250 V for 100~120 V~;
T 2,0 AL, 250 V for 220-240 V~
For model SB 30 SUB:
T 4.0AL, 250V
For model SB 30 SUB/230:
T 2.5 AL, 250 V
T 4.0 AL, 250 V for 100~120 V~;
T 2,0 AL, 250 V for 220-240 V~
For model SB 30 SUB:
T 4.0AL, 250V
For model SB 30 SUB/230:
T 2.5 AL, 250 V
Pass
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
See appended table 13
Pass
14.5.1.1
a) Thermal cut-outs separately approved
No such Thermal cut-outs.
N/A
b) Thermal cut-outs tested as part of the
submission
submission
N/A
14.5.1.2
a) Thermal links separately approved
No such Thermal links.
N/A
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
No such devices.
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
See table 14.
Pass