Report No. : 12-1330-0135
IEC/EN 60065
Clause
Requirement
– Test
Result - Remark
Verdict
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22)
sheet insulation. See 8.22)
Insulating tape in transformer.
Pass
Basic or supplementary insulation, at least two
layers, each meeting 10.3 dielectric
layers, each meeting 10.3 dielectric
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3 dielectric
two of which meet 10.3 dielectric
N/A
Reinforced insulation, two layers each of which
meet 10.3 dielectric
meet 10.3 dielectric
N/A
Reinforced insulation, three layers any two which
meet 10.3 dielectric
meet 10.3 dielectric
Three layers of insulation tape
provided between hazardous
live winding and non-hazards
live winding of transformer.
Each two layers passes
dielectric strength test at
4240Vdc.
provided between hazardous
live winding and non-hazards
live winding of transformer.
Each two layers passes
dielectric strength test at
4240Vdc.
Pass
8.9
Primary Wiring: Adequate insulation between
internal hazardous live conductors and accessible
parts
internal hazardous live conductors and accessible
parts
Measured min. 0.4mm
Pass
Secondary Wiring: Adequate insulation between
internal hazardous live parts and conductors
connected to accessible parts
internal hazardous live parts and conductors
connected to accessible parts
Measured min. 0.4mm
Pass
8.10
Class II Wiring:
(1) Primary: Double insulation between conductors
connected to the mains and accessible parts.
connected to the mains and accessible parts.
(2) Secondary: Double insulation between
conductors connected to accessible parts and the
mains
conductors connected to accessible parts and the
mains
Pass
8.11
Detaching of wires
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
No wire could be become
detached.
detached.
Pass
Vibration test carried out ......................................... : See sub-clause 12.1.2
Pass
8.12
This sub-clause is void
Complied
Pass
8.13
Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s)
covers etc. (pull test 20 N for 10 s)
No windows, lenses, lamp
covers etc.
covers etc.
N/A
8.14
Adequate fastening of covers (pull test 50 N for
10 s)
10 s)
No cover.
N/A
8.15
No risk of damage to the insulation of internal
wiring due to hot parts or sharp edges (2N force)
wiring due to hot parts or sharp edges (2N force)
Complied.
Pass
8.16
Only special supply equipment can be used
No such supply equipment used.
N/A
8.17
Insulated winding wire without additional
interleaved insulation
interleaved insulation
No insulated winding wires are
employed.
employed.
N/A
8.18
Endurance test as required by 8.17
Same as above.
N/A
8.19
Disconnection from the mains
Pass