Read Harman Kardon HS 100 EU (serv.man14) EMC - CB Certificate online
page 10 of 51
Ref. No. : JSH05090075-001
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
12.4
Drawers (pull test 50 N, 10 s)
Pass
12.5
Antenna coaxial sockets providing isolation
N/A
12.6
Telescoping or rod antennas construction
N/A
12.6.1
Telescoping or rod antennas securement
N/A
13
CLEARANCE AND CREEPAGE DISTANCES
Pass
13.1
Clearances in accordance with 13.3
Pass
Creepage distances in accordance with 13.4
Pass
13.2
Determination of operating voltage
TR1: pin3- 13, 340Vrms,
1.0kVp
1.0kVp
TR2: pin1-8,9,10, 280Vrms,
420Vp
420Vp
Pass
13.3 Clearances
Primary—secondary: 4.0mm
required
required
Primary (operating voltage:
240Vrms) —accessible parts /
enclosure: 4.0mm required
240Vrms) —accessible parts /
enclosure: 4.0mm required
Primary (operating voltage:
340Vrms, 1.0kVp) —
accessible parts / enclosure:
5.9mm required
340Vrms, 1.0kVp) —
accessible parts / enclosure:
5.9mm required
L-N before fuse link:
2.0mm required
TR1: P—S: 5.9mm required
TR2: P—S: 4.0mm required
Pass
13.3.2
Circuits conductively connected to the mains comply
with table 8 and, where applicable, table 9
with table 8 and, where applicable, table 9
Measured distance:
Primary—secondary: >4.6mm
Primary—accessible parts /
enclosure (operating voltage:
240Vrms): >4.6mm
enclosure (operating voltage:
240Vrms): >4.6mm
Primary—accessible parts /
enclosure (operating voltage:
340Vrms, 1.0kVp): >10mm
enclosure (operating voltage:
340Vrms, 1.0kVp): >10mm
TR1: P—S: >6.0mm
TR2: P—S: >6.0mm
L-N before fuse link: >3.5mm
Pass
Click on the first or last page to see other HS 100 EU (serv.man14) service manuals if exist.