HS 100 EU (serv.man14) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 11

Read Harman Kardon HS 100 EU (serv.man14) EMC - CB Certificate online

 
 
page 10 of  51 
Ref. No. : JSH05090075-001 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
12.4 
Drawers (pull test 50 N, 10 s) 
 
Pass 
12.5 
Antenna coaxial sockets providing isolation 
 
N/A 
12.6 
Telescoping or rod antennas construction 
 
N/A 
12.6.1 
Telescoping or rod antennas securement 
 
N/A 
 
 
 
13 
CLEARANCE AND CREEPAGE DISTANCES 
Pass 
13.1 
Clearances in accordance with 13.3 
 
Pass 
 
Creepage distances in accordance with 13.4 
  
Pass 
13.2 
Determination of operating voltage 
TR1: pin3- 13, 340Vrms, 
1.0kVp 
TR2: pin1-8,9,10, 280Vrms, 
420Vp  
Pass 
13.3 Clearances 
Primary—secondary: 4.0mm 
required 
Primary (operating voltage: 
240Vrms) —accessible parts / 
enclosure: 4.0mm required 
Primary (operating voltage: 
340Vrms, 1.0kVp) —
accessible parts / enclosure: 
5.9mm required 
L-N before fuse link:  
2.0mm required 
TR1: P—S: 5.9mm required 
TR2: P—S: 4.0mm required 
Pass 
13.3.2 
Circuits conductively connected to the mains comply 
with table 8 and, where applicable, table 9 
Measured distance:  
Primary—secondary: >4.6mm 
Primary—accessible parts / 
enclosure (operating voltage: 
240Vrms): >4.6mm 
Primary—accessible parts / 
enclosure (operating voltage: 
340Vrms, 1.0kVp): >10mm 
TR1: P—S: >6.0mm 
TR2: P—S: >6.0mm 
L-N before fuse link: >3.5mm
 
Pass 
Page of 52