Ref. No. : JSH05090075-001
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
6 HAZARDOUS
RADIATION
Pass
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No ionizing radiation
N/A
6.1
EN 60065
European Council Directive 96/29/Euratom of 13
May 1996 10cm from outer surface of apparatus
<1µSv/h (0,1mR/h)
May 1996 10cm from outer surface of apparatus
<1µSv/h (0,1mR/h)
No ionizing radiation
N/A
6.2
Laser radiation, emission limits to IEC 60825-1 .... : Class 1
Pass
Emission limits under fault conditions .................... : Laser Optical Pickup:Class 1
Pass
7
HEATING UNDER NORMAL OPERATING CONDITIONS
Pass
7.1
Temperature rises not exceeding specified values,
no operation of fuse links
no operation of fuse links
(see appended table)
Pass
7.1.1
Temperature rise of accessible parts
(see appended table)
Pass
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table)
Pass
7.1.3
Temperature rise of parts acting as a support or as a
mechanical barrier
mechanical barrier
(see appended table)
Pass
7.1.4
Temperature rise of windings
(see appended table)
Pass
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table)
Pass
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
No such supporting parts
N/A
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
Pass
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
PCB, windings
Pass
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
Tools are required
Pass
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No hygroscopic material used
Pass
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
cover which can be removed by hand
Tools are required
Pass
8.5
Class I equipment
N/A
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N/A
Resistors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
N/A