Ref. No. : JSH05090075-001 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10 
Such circuits are secondary 
circuit and do not include 
hazardous voltage, no basic, 
supplementary or reinforced 
insulation required. 
N/A 
13.4 Creepage 
distances 
Primary—secondary:
 
on PCB 
track 4.0mm required (PCB 
material group I or II). 
Primary—accessible parts / 
enclosure (operating voltage: 
240Vrms): on PCB track 
4.0mm required (PCB material 
group I or II). 
Primary—accessible parts / 
enclosure (operating voltage: 
340Vrms, 1.0kVp): on PCB 
track 5.9mm required (PCB 
material group I or II). 
L-N before fuse link:  
3.0mm required 
TR1: P—S: 5.9mm required 
(insulation tape material group 
I; margin tape material group II; 
PCB material group I or II). 
TR2: P—S: 4.4mm required 
(insulation tape material group 
I; margin tape material group II; 
PCB material group I or II). 
Pass 
 
Creepage distances greater than table 11 minima 
Measured distance:  
Primary—secondary: >6.0mm 
Primary—accessible parts / 
enclosure (operating voltage: 
240Vrms): >6.0mm 
Primary—accessible parts / 
enclosure (operating voltage: 
340Vrms, 1.0kVp): >15mm 
TR1: P—S: >6.0mm 
TR2: P—S: >6.0mm 
L-N before fuse link: >3.5mm 
Pass 