 Report 
No.JSH05090075-001 
 
                  IEC  60825-1 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065D 
 
     TRF originator BEAB 
Details of measurement procedure and measurement results: 
 
Step 
 
specified / measured / calculated 
unit 
Classification, Laser Class 
----- 
Typical wavelength of laser diode 
λ = 795 (CD) 
λ = 658 (DVD) 
nm  
nm 
Emission duration 
t = ∞(see 9.4) 
Time basis 
T = 100 
s  
Size of apparent source  
assumed extended source at outside 
mm 
Angular subtense 
α < αmin  
mrad 
Limiting angular subtense 
α
min 
= 1.5  
mrad  
Angle of acceptance 
α
max 
= 100  
mrad 
Diameter of aperture stop 
d = 7  
mm 
Distance of aperture stop to source 
r = 14  
mm 
 
 
 
Calculation of AEL (Class as above) : 
(Radiant Power 
[W]
 
Used formula 
(CD)Class 1: 3.9 x 10
-4
 C
4
C
7
 
(DVD)Class 1: 3.9 x 10
-4
 
Used correction factors 
C
4
=10
0.002(
λ
-700)
=1.55 
C
7
=1 
 
Accessible emission limit 
(CD)Class 1: AEL
radiant 
= 0.605 
(DVD) Class 1: AEL
radiant 
= 0.390 
mW 
mW 
 
 
 
Measurement results:  
Class 1  
 
Normal condition 
(CD)Pm
 
= 0.052 
(DVD) Pm
 
= 0.053 
mW 
mW 
Abnormal condition: 
Total output power 
(CD)Pm
 
= 0.234 
(DVD) Pm
 
= 0.258 
mW 
mW 
 
 
 
 
 