Read Harman Kardon HS 100 EU (serv.man14) EMC - CB Certificate online
page 13 of 51
Ref. No. : JSH05090075-001
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
14.3
Inductors and windings
Pass
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
N/A
14.3.1
Transformers and inductors marked with
manufacturer's name and type .............................. :
manufacturer's name and type .............................. :
Switching mode transformer
TR1: BCK-ER2802S1
TR2: BCK-EC4201A
Inductor LF1: 203A
Inductor LF2: UF1601
Pass
Transformers and inductors separately approved . : No
N/A
14.3.2 General
Pass
14.3.3 Constructional
requirements
Pass
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
Pass
14.3.3.2
Transformers meet the constructional requirements
Pass
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
TR1 basic insulation minimum
5.3 mm between TR1 core
and primary, Supplementary
insulation minimum 4.0mm
between TR1 core and
secondary.
TR2 basic insulation minimum
4.0 mm between TR2 core
and primary, Supplementary
insulation minimum
5.3 mm between TR1 core
and primary, Supplementary
insulation minimum 4.0mm
between TR1 core and
secondary.
TR2 basic insulation minimum
4.0 mm between TR2 core
and primary, Supplementary
insulation minimum
4.0mm
between TR2 core and
secondary.
secondary.
Pass
Coil formers and partition walls > 0,4 mm
TR1, TR2 bobbin: 0.8mm
Pass
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
Class II construction
N/A
14.3.4.3
Separating transformers with at least basic
insulation
insulation
N/A
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Iron cores in TR1 and TR2 are
not connected to primary parts
or accessible parts.
not connected to primary parts
or accessible parts.
Pass
Coil formers and partition walls > 0,4 mm
TR1, TR2 bobbin: 0.8mm
Pass
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
Class II construction
N/A
Click on the first or last page to see other HS 100 EU (serv.man14) service manuals if exist.