Read Harman Kardon HS 100 EU (serv.man14) EMC - CB Certificate online
page 6 of 51
Ref. No. : JSH05090075-001
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
8.6
Class II equipment and Class II constructions within
Class I equipment
Class I equipment
Pass
Reinforced or double insulation between hazardous
live parts and accessible parts
live parts and accessible parts
Pass
Components bridging reinforced or double insulation
complying with 14.1 a) or 14.3
complying with 14.1 a) or 14.3
TR1, TR2
Pass
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
bridged by a capacitor complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged with 2
capacitors in series complying with 14.2.1 a)
capacitors in series complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged with a
single capacitor complying with 14.2.1 b)
single capacitor complying with 14.2.1 b)
CY1, CY2, CY3, CY4, CY5,
CY6
CY6
Pass
Basic insulation bridged by components complying
with 14.3.4.3
with 14.3.4.3
N/A
8.7
Basic insulation between parts at 35 V to 71 V
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
No such voltage
N/A
Reinforced or double insulation between circuits
operating at voltages between 35 V and 71 V (peak)
a.c. or between 60 V and 120 V d.c. and hazardous
live parts at higher voltage
operating at voltages between 35 V and 71 V (peak)
a.c. or between 60 V and 120 V d.c. and hazardous
live parts at higher voltage
N/A
Separation by Class II isolating transformer
N/A
Separation by Class I transformer
N/A
Separation by earthed conductive part
N/A
8.8
Basic or supplementary insulation > 0,4 mm (mm) :
N/A
Reinforced insulation > 0,4 mm (mm) .................... : TR1, TR2 bobbin: 0.8mm
Optocoupler PH1, PH2:
0.45mm
0.45mm
Enclosure: >1.1mm
Separation sheet on internal
enclosure under power board:
0.5mm.
enclosure under power board:
0.5mm.
Pass
Thin sheet insulation
Inside TR1, TR2
Pass
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N/A
Reinforced insulation, two layers each of which meet
10.3
10.3
N/A
Click on the first or last page to see other HS 100 EU (serv.man14) service manuals if exist.