HKTS 11 (serv.man13) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 19

Read Harman Kardon HKTS 11 (serv.man13) EMC - CB Certificate online

 
Page 13 of 48 
Report Ref No.: 615320 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
 
13 
CLEARANCE AND CREEPAGE DISTANCES 
 
13.1 
Clearances in accordance with 13.3 
Prim – sec. >10mm 
Prim – acc. metal parts : 6mm 
 
Creepage distances in accordance with 13.4 
 
13.2 
Determination of operating voltage 
See TABLE 13 
13.3 
Clearances 
 
 
13.3.2 
Circuits conductively connected to the mains 
comply with table 8 and, where applicable,  
table 9 
 P 
13.3.3 
Circuits not conductively connected to the 
mains comply with table 10 
Circuits not conductively connected to 
the mains cannot cause any shock 
hazard. 
N/A 
13.3.4 
Measurement of transient voltages 
 
N/A 
13.4 
Creepage distances 
 
 
 
Creepage distances greater than table 11 
minima 
 P 
13.5 
Printed boards 
 
 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of 
which may be conductively connected to the 
mains, as in fig. 10 
 N/A 
13.5.2 
Type B coated printed circuit boards complying 
with IEC 60664-3 (basic insulation only) 
 N/A 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply 
with 13.3 and 13.4 
 N/A 
 
Conductive parts along reliably cemented joints 
comply with 8.8 
 N/A 
13.7 
Enclosed, enveloped or hermetically sealed 
parts: not conductively connected to the mains: 
clearances and creepage distances as in 
table 12 
 N/A 
13.8 Parts 
filled with insulating compound, meeting 
the requirements of 8.8 
 N/A 
 
Page of 62
Display