HKTS 11 (serv.man13) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 21

Read Harman Kardon HKTS 11 (serv.man13) EMC - CB Certificate online

 
Page 15 of 48 
Report Ref No.: 615320 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible 
parts (double or reinforced insulation) 
Prim.-sec: > 10mm 
 
 
Coil formers and partition walls ≥ 0,4 mm 
1.3mm 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met 
 N/A 
14.3.4.3 
Separating transformers with at least basic 
insulation 
 N/A 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible 
parts (double or reinforced insulation) 
Prim.-iron core >10mm 
 
Coil formers and partition walls = 0,4 mm 
Thin sheet 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective 
earth terminal 
 N/A 
 
Winding wires connected to protective earth 
have adequate current-carrying capacity 
 N/A 
14.4 
High voltage components 
 
 
High-voltage components and assemblies: 
U > 4 kV (peak) separately approved 
 N/A 
 
Component meets category V-1 of IEC 60707 
 
N/A 
14.4.1 
High voltage transformers and multipliers tested 
as part of the submission 
 N/A 
14.4.2 
High voltage assemblies and other parts tested 
as part of the submission 
 N/A 
14.5 
Protective devices 
 
 
Protective devices used within their ratings 
 
 
External clearances and creepage distances 
meet requirement of clause 13 for the voltage 
across the device when opened 
 P 
14.5.1.1 
a) Thermal cut-outs separately approved 
 
N/A 
 
b) Thermal cut-outs tested as part of the 
submission 
Did not open during fault conditions 
N/A 
14.5.1.2 
a) Thermal links separately approved 
 
N/A 
 
b) Thermal links tested as part of the 
submission 
In transformer G4M20403-0857-L        
Did not open during fault conditions 
N/A 
14.5.1.3 
Thermal devices re-settable by soldering 
 
N/A 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 
60127 
 P 
Page of 62
Display