Read Harman Kardon HKTS 11 (serv.man13) EMC - CB Certificate online
Page 15 of 48
Report Ref No.: 615320
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible
parts (double or reinforced insulation)
between hazardous live parts and accessible
parts (double or reinforced insulation)
Prim.-sec: > 10mm
P
Coil formers and partition walls ≥ 0,4 mm
1.3mm
P
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
N/A
14.3.4.3
Separating transformers with at least basic
insulation
insulation
N/A
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible
parts (double or reinforced insulation)
between hazardous live parts and accessible
parts (double or reinforced insulation)
Prim.-iron core >10mm
P
Coil formers and partition walls = 0,4 mm
Thin sheet
P
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective
earth terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective
earth terminal
N/A
Winding wires connected to protective earth
have adequate current-carrying capacity
have adequate current-carrying capacity
N/A
14.4
High voltage components
High-voltage components and assemblies:
U > 4 kV (peak) separately approved
U > 4 kV (peak) separately approved
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested
as part of the submission
as part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested
as part of the submission
as part of the submission
N/A
14.5
Protective devices
Protective devices used within their ratings
P
External clearances and creepage distances
meet requirement of clause 13 for the voltage
across the device when opened
meet requirement of clause 13 for the voltage
across the device when opened
P
14.5.1.1
a) Thermal cut-outs separately approved
N/A
b) Thermal cut-outs tested as part of the
submission
submission
Did not open during fault conditions
N/A
14.5.1.2
a) Thermal links separately approved
N/A
b) Thermal links tested as part of the
submission
submission
In transformer G4M20403-0857-L
Did not open during fault conditions
Did not open during fault conditions
N/A
14.5.1.3
Thermal devices re-settable by soldering
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
P