Read Harman Kardon HKTS 11 (serv.man13) EMC - CB Certificate online
Page 10 of 48
Report Ref No.: 615320
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
9.1
Testing on the outside
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
N/A
9.1.1.1
a)
a)
Determination of Hazardous Live parts
P
b) Touch current measured from terminal devices
using the network in annex D ........................... :
See TABLE 9.1
P
c) Discharge not exceeding 45 μC
N/A
d) Energy of discharge not exceeding 350 mJ
N/A
9.1.1.2
Test with test finger and test probe
P
9.1.2
No hazardous live shafts of knobs, handles or
levers
levers
P
9.1.3
Ventilation holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
No ventilation holes on top.
N/A
9.1.4
Terminal devices - within 25mm tested with
1 mm x 20 mm test pin (10 N); test probe D of
IEC 61032
1 mm x 20 mm test pin (10 N); test probe D of
IEC 61032
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm
test pin (10 N); test probe C of IEC 61032
test pin (10 N); test probe C of IEC 61032
N/A
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after 2 s :
withdrawal of the mains plug; voltage (V) after 2 s :
0V
P
If C is not greater than 0,1 μF no test needed
N/A
9.1.7
Enclosure sufficiently resistant to external force
a)
Test probe 11 of IEC 61032 for 10 s (50 N)
P
b)
Test hook of fig. 4 for 10 s (20 N)
P
c)
Conductive enclosure: 30 mm diameter test tool
for 5 s (100 or 250 N) ........................................ :
for 5 s (100 or 250 N) ........................................ :
250N
P
9.2
No hazard 2s after removing a cover by hand
N/A
Click on the first or last page to see other HKTS 11 (serv.man13) service manuals if exist.