Report Ref No.: 615320 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
 
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS 
 
9.1 
Testing on the outside 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
 N/A 
9.1.1.1    
a) 
Determination of Hazardous Live parts 
 
b)  Touch current measured from terminal devices 
using the network in annex D  ........................... :
See TABLE 9.1 
c)  Discharge not exceeding 45 μC  
N/A 
d)  Energy of discharge not exceeding 350 mJ 
 
N/A 
9.1.1.2 
Test with test finger and test probe 
 
9.1.2 
No hazardous live shafts of knobs, handles or 
levers 
 P 
9.1.3 
Ventilation holes tested by means of 
4 mm x 100 mm test pin 
No ventilation holes on top. 
N/A 
9.1.4 
Terminal devices - within 25mm tested with 
1 mm x 20 mm test pin (10 N); test probe D of 
IEC 61032 
 P 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032 
 P 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm 
test pin (10 N); test probe C of IEC 61032 
 N/A 
9.1.6 
No shock hazard due to stored charge on 
withdrawal of the mains plug; voltage (V) after 2 s :
                                                              
0V 
 
If C is not greater than 0,1 μF no test needed 
 
N/A 
9.1.7 
Enclosure sufficiently resistant to external force 
a) 
Test probe 11 of IEC 61032 for 10 s (50 N) 
 
b) 
Test hook of fig. 4 for 10 s (20 N) 
 
c) 
Conductive enclosure: 30 mm diameter test tool 
for 5 s (100 or 250 N) ........................................ :
 
250N 
9.2 
No hazard 2s after removing a cover by hand 
 
N/A 
 
 
Page of 62